Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The true sensitivity of a cancer screening test, defined as the frequency with which the test returns a positive result if the cancer is present, is a key indicator of diagnostic performance. Given the challenges of directly assessing test sensitivity in a prospective screening program, proxy measures for true sensitivity are frequently reported. We call one such proxy empirical sensitivity, as it is given by the observed ratio of screen-detected cancers to the sum of screen-detected and interval cancers. In the setting of the canonical three-state Markov model for progression from preclinical onset to clinical diagnosis, we formulate a mathematical relationship for how empirical sensitivity varies with the screening interval and the mean preclinical sojourn time and identify conditions under which empirical sensitivity exceeds or falls short of true sensitivity. In particular, when the inter-screening interval is short relative to the mean sojourn time, empirical sensitivity tends to exceed true sensitivity, unless true sensitivity is high. The Breast Cancer Surveillance Consortium (BCSC) has reported an estimate of 0.87 for the empirical sensitivity of digital mammography. We show that this corresponds to a true sensitivity of 0.82 under a mean sojourn time of 3.6 years estimated based on breast cancer screening trials. However, the BCSC estimate of empirical sensitivity corresponds to even lower true sensitivity under more contemporary, longer estimates of mean sojourn time. Consistently applied nomenclature that distinguishes empirical sensitivity from true sensitivity is needed to ensure that published estimates of sensitivity from prospective screening studies are properly interpreted.

Download full-text PDF

Source
http://dx.doi.org/10.1177/09622802221142529DOI Listing

Publication Analysis

Top Keywords

true sensitivity
32
empirical sensitivity
28
sensitivity
17
sojourn time
16
sensitivity prospective
12
cancer screening
12
test sensitivity
8
screening program
8
true
8
prospective screening
8

Similar Publications

Deviance detection and regularity sensitivity in dissociated neuronal cultures.

Front Neural Circuits

September 2025

Department of Mechano-Informatics, Graduate School of Information Science and Technology, The University of Tokyo, Tokyo, Japan.

Introduction: Understanding how neural networks process complex patterns of information is crucial for advancing both neuroscience and artificial intelligence. To investigate fundamental principles of neural computation, we examined whether dissociated neuronal cultures, one of the most primitive living neural networks, exhibit regularity sensitivity beyond mere stimulus-specific adaptation and deviance detection.

Methods: We recorded activity to oddball electrical stimulation paradigms from dissociated rat cortical neurons cultured on high-resolution CMOS microelectrode arrays.

View Article and Find Full Text PDF

Diagnostic tips for multi-phase post-mortem computed tomography angiography interpretation in upper gastro-intestinal bleeding.

Int J Legal Med

September 2025

University Center of Legal Medicine Lausanne-Geneva, University of Geneva, Geneva University Hospitals, Rue Michel-Servet 1, 1211, Geneva 4, Switzerland.

In the past 10 years, the Multi-phase Post-mortem Computed Tomography Angiography (MPMCTA) has considerably improved the quality and precision of postmortem diagnoses, particularly in cases with vascular implication. MPMCTA is known to have higher sensitivity for detecting the source of a hemorrhage than autopsy. Death by upper gastro-intestinal (GI) bleeding is not so uncommon in forensic practice.

View Article and Find Full Text PDF

Echolocating bats provide vital ecosystem services and can be monitored effectively using passive acoustic monitoring (PAM) techniques. Duty-cycle subsampling is widely used to collect PAM data at regular ON/OFF cycles to circumvent battery and storage capacity constraints for long-term monitoring. However, the impact of duty-cycle subsampling and potential detector errors on estimating bat activity has not been systematically investigated for bats.

View Article and Find Full Text PDF

Accurate timing estimates of when participants acquire HIV in HIV prevention trials are necessary for determining antibody levels at acquisition. The Antibody-Mediated Prevention (AMP) Studies showed that a passively administered broadly neutralizing antibody can prevent the acquisition of HIV from a neutralization-sensitive virus. We developed a pipeline for estimating the date of detectable HIV acquisition (DDA) in AMP Study participants using diagnostic and viral sequence data.

View Article and Find Full Text PDF

Use of a Screening Tool for Dementia in a Down Syndrome Specialty Clinic.

Am J Med Genet A

September 2025

Down Syndrome Program, Division of Medical Genetics and Metabolism, Department of Pediatrics, Massachusetts General Hospital, Boston, Massachusetts, USA.

To study the use of a dementia screening tool in our clinic cohort of adults with Down syndrome. To evaluate the functionality of the NTG-EDSD for Dementia as part of a dementia screening protocol for adults with Down syndrome, we conducted a cohort analysis of patients aged 40 and older followed at the Massachusetts General Hospital Down Syndrome Program, noting any clinical interpretation of dementia or mild cognitive impairment (MCI). From September 2023 to September 2024, 54 NTG-EDSD responses were collected.

View Article and Find Full Text PDF