Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: F-FDG PET/CT imaging allows to study oncological patients and their relative diagnosis through the standardised uptake value (SUV) evaluation. During radiopharmaceutical injection, an extravasation event may occur, making the SUV value less accurate and possibly leading to severe tissue damage. The study aimed to propose a new technique to monitor and manage these events, to provide an early evaluation and correction to the estimated SUV value through a SUV correction coefficient.

Methods: A cohort of 70 patients undergoing F- FDG PET/CT examinations was enrolled. Two portable detectors were secured on the patients' arms. The dose-rate (DR) time curves on the injected DR and contralateral DR arm were acquired during the first 10 min of injection. Such data were processed to calculate the parameters Δp = (DR- DR)/DR and ΔR = (DR(t) - DR(t)), where DR is the maximum DR value, DR is the average DR value in the injected arm. OLINDA software allowed dosimetric estimation of the dose in the extravasation region. The estimated residual activity in the extravasation site allowed the evaluation of the SUV's correction value and to define an SUV correction coefficient.

Results: Four cases of extravasations were identified for which ΔR [(390 ± 26) µSv/h], while ΔR [(150 ± 22) µSv/h] for abnormal and ΔR [(24 ± 11) µSv/h] for normal cases. The Δp showed an average value of (0.44 ± 0.05) for extravasation cases and an average value of (0.91 ± 0.06) and (0.77 ± 0.23) in normal and abnormal classes, respectively. The percentage of SUV reduction (SUV) ranges between 0.3% and 6%. The calculated self-tissue dose values range from 0.027 to 0.573 Gy, according to the segmentation modality. A similar correlation between the inverse of Δp and the normalised ΔR with the SUV correction coefficient was found.

Conclusions: The proposed metrics allowed to characterised the extravasation events in the first few minutes after the injection, providing an early SUV correction when necessary. We also assume that the characterisation of the DR-time curve of the injection arm is sufficient for the detection of extravasation events. Further validation of these hypotheses and key metrics is recommended in larger cohorts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10205949PMC
http://dx.doi.org/10.1186/s40658-023-00556-5DOI Listing

Publication Analysis

Top Keywords

suv correction
16
extravasation events
12
suv
10
detection extravasation
8
extravasation
7
correction
7
safety injections
4
injections nuclear
4
nuclear medicine
4
medicine radiotracers
4

Similar Publications

Background: Animal models of nerve compression have revealed neuroinflammation not only at the entrapment site, but also remotely at the spinal cord. However, there is limited information on the presence of neuroinflammation in human compression neuropathies. The objectives of this study were to: (1) assess which tracer kinetic model most optimally quantified [C]DPA713 uptake in the spinal cord and neuroforamina in patients with painful cervical radiculopathy, (2) evaluate the performance of linearized methods (e.

View Article and Find Full Text PDF

Purpose: The liver-brain axis regulates metabolic homeostasis, with glucose metabolism playing a key role. Liver dysfunction, such as fibrosis, may impact brain metabolism and consequently, brain function. Positron emission tomography (PET) imaging provides a non-invasive approach to study glucose metabolism in both organs.

View Article and Find Full Text PDF

Accurate interpretation of quantitative positron emission tomography (PET)outcomes hinges on understanding the test-retest variability (T-RT).Previous studies of the tau-PET ligand [F]MK-6240 reported adequateT-RT performance of tau burden estimates over a short-term 21-day and over alonger-term 6-month T-RT period, primarily involving Alzheimer's disease(AD) and cognitively normal (CN) subjects, respectively. However, several T-RTcharacteristics have not yet been reported, particularly in older CN (oCN)subjects.

View Article and Find Full Text PDF

Structured Report Generation for Breast Cancer Imaging Based on Large Language Modeling: A Comparative Analysis of GPT-4 and DeepSeek.

Acad Radiol

August 2025

Department of Nuclear Medicine, Zhejiang Cancer Hospital, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou, Zhejiang 310022, China (K.C., H.Y.). Electronic address:

Rationale And Objectives: The purpose of this study is to compare the performance of GPT-4 and DeepSeek large language models in generating structured breast cancer multimodality imaging integrated reports from free-text radiology reports including mammography, ultrasound, MRI, and PET/CT.

Materials And Methods: A retrospective analysis was conducted on 1358 free-text reports from 501 breast cancer patients across two institutions. The study design involved synthesizing multimodal imaging data into structured reports with three components: primary lesion characteristics, metastatic lesions, and TNM staging.

View Article and Find Full Text PDF

Purpose: Positron range correction (PRC) can mitigate the effect of the larger positron range on the image quality of Gallium-68 (Ga) PET-imaging. The aim of this study is to evaluate the improvement in Ga-PET image quality by applying a tissue-dependent and spatially-variant PRC (TDSV PRC) for Ga in a clinical setting.

Methods: A TDSV PRC technique was developed employing CT-driven segmentation masks of different tissue types (soft tissue, bone, lung) and the corresponding tissue-specific positron range kernels.

View Article and Find Full Text PDF