A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Recalibrating polyparameter linear free energy relationships and reanalyzing mechanisms for partition of nonionic organic compounds to low-density polyethylene passive sampler. | LitMetric

Recalibrating polyparameter linear free energy relationships and reanalyzing mechanisms for partition of nonionic organic compounds to low-density polyethylene passive sampler.

J Chromatogr A

Department of Municipal Engineering, School of Civil Engineering, Southeast University, Nanjing 210096, Jiangsu, China. Electronic address:

Published: July 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Equilibrium passive sampling techniques based on the low-density polyethylene (LDPE) film are increasingly used for determining the concentration of contaminants in water and air. Reliable models capable of predicting LDPE-water and LDPE-air partition coefficients (K and K) would be very useful. In previous studies, polyparameter linear free energy relationships (PP-LFERs) based on Abraham's solute descriptors were calibrated for LDPE-water and LDPE-air systems. Unfortunately, a portion of unreliable partition coefficients and solute descriptors were included in the calibration sets of these previous studies, leading to unexpected system parameters and predictive performance in the regression results. In this study, more reliable PP-LFERs were recalibrated for LDPE-water and LDPE-air systems (20‒25 °C) using carefully collected reliable partition coefficients and solute descriptors of various polar and nonpolar compounds (over one hundred and with low redundancy) from the literature, as well as the robust regression method. The PP-LFERs performed well with root-mean-square errors of 0.15-0.25 log units and successfully predicted K and K values spanning over 10 orders of magnitude for compounds with reliable descriptors. The partitioning mechanisms of compounds to LDPE were also reanalyzed and compared in detail with n-alkanes (C-C). Generally, LDPE is more prone to form dispersion interactions with solutes than n-alkanes, while it is more difficult to form cavities in LDPE. In addition, the crystallinity of LDPE is not the sole reason for the distinct constant terms presenting in PP-LFERs for LDPE-water and n-hexadecane-water systems.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2023.464039DOI Listing

Publication Analysis

Top Keywords

ldpe-water ldpe-air
12
partition coefficients
12
solute descriptors
12
polyparameter linear
8
linear free
8
free energy
8
energy relationships
8
low-density polyethylene
8
previous studies
8
ldpe-air systems
8

Similar Publications