98%
921
2 minutes
20
Purpose: The development of online-adaptive proton therapy (PT) is essential to overcome limitations encountered by day-to-day variations of the patient's anatomy. Range verification could play an essential role in an online feedback loop for the detection of treatment deviations such as anatomical changes. Here, we present the results of the first systematic patient study regarding the detectability of anatomical changes by a prompt-gamma imaging (PGI) slit-camera system.
Methods And Materials: For 15 patients with prostate cancer, PGI measurements were performed during 105 fractions (201 fields) with in-room control computed tomography (CT)acquisitions. Field-wise doses on control CT scans were manually classified as whether showing relevant or non-relevant anatomical changes. This manual classification of the treatment fields was then used to establish an automatic field-wise ground truth based on spot-wise dosimetric range shifts, which were retrieved from integrated depth-dose (IDD) profiles. To determine the detection capability of anatomical changes with PGI, spot-wise PGI-based range shifts were initially compared with corresponding dosimetric IDD range shifts. As final endpoint, the agreement of a developed field-wise PGI classification model with the field-wise ground truth was determined. Therefore, the PGI model was optimized and tested for a subcohort of 131 and 70 treatment fields, respectively.
Results: The correlation between PGI and IDD range shifts was high, ρ = 0.67 (p < 0.01). Field-wise binary PGI classification resulted in an area under the curve of 0.72 and 0.80 for training and test cohorts, respectively. The model detected relevant anatomical changes in the independent test cohort, with a sensitivity and specificity of 74% and 79%, respectively.
Conclusions: For the first time, evidence of the detection capability of anatomical changes in prostate-cancer PT from clinically acquired PGI data is shown. This emphasizes the benefit of PGI-based range verification and demonstrates its potential for online-adaptive PT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijrobp.2023.05.002 | DOI Listing |
Orthop Res Rev
September 2025
Department of Orthopedics and Sports Medicine, Houston Methodist Hospital, Houston, TX, USA.
Objective: The incidence of total shoulder arthroplasty (TSA) in the United States continues to climb as an aging yet active population increases demand for the procedure. Due to promising clinical results out of Europe, improvement in prosthesis design, and wider acceptance of reverse total shoulder arthroplasty (rTSA), this study was designed to evaluate how rTSA and anatomical TSA (aTSA) utilization, patient selection, and length of stay have changed at a single institution.
Methods: This was a retrospective cohort study of patients from one hospital system between 2017 and 2023.
Radiol Case Rep
November 2025
Department of Radiology and Diagnostic Imaging, Fundación Cardioinfantil-Instituto de Cardiología, St. 163a #13B-60, Bogotá, Colombia.
Obturator hernia is a rare but clinically significant cause of intestinal obstruction, particularly in elderly, thin women due to their anatomical predisposition. We present the case of a 79-year-old female with a history of hypertension and hip arthroplasty who developed acute abdominal pain, vomiting, and absence of flatus and bowel movements. Imaging with contrast-enhanced computed tomography (CT) revealed a right obturator hernia containing a small bowel loop, causing intestinal obstruction without signs of ischemia.
View Article and Find Full Text PDFCureus
August 2025
Midwifery Department, University of West Attica, Athens, GRC.
Cardiopulmonary resuscitation (CPR) is a critical, life-saving intervention. In pregnant women, unique anatomical and physiological changes require adaptations to standard CPR protocols to ensure optimal outcomes for both mother and fetus, emphasizing the need for universal awareness and standardized training across diverse healthcare systems globally. Despite the high-risk nature of maternal cardiac arrest, evidence suggests that many healthcare professionals may not be adequately prepared to respond effectively.
View Article and Find Full Text PDFWound Repair Regen
September 2025
Institute of Microsurgery on Extremities, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
This study aimed to develop an acellular dermal matrix derived from tilapia skin and evaluate its potential as a bioscaffold for skin wound repair. Structural and compositional changes before and after decellularisation were assessed through histological staining, electron microscopy and immunological analysis. The matrix exhibited low immunogenicity, preserved extracellular matrix architecture and retained key bioactive components.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDF