Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The 3∼5 µm mid-infrared (mid-IR) light has several exceptional benefits in the case of adverse atmospheric conditions compared to the 1.5 µm band, so it is a promising candidate for optical carriers for free-space communication (FSO) through atmospheric channels. However, the transmission capacity in the mid-IR band is constrained in the lower range due to the immaturity of its devices. In this work, to replicate the 1.5 µm band dense wavelength division multiplexing (DWDM) technology to the 3 µm band for high-capacity transmission, we demonstrate a 12-channel 150 Gbps FSO transmission in the 3 µm band based on our developed mid-IR transmitter and receiver modules. These modules enable wavelength conversion between the 1.5 µm and 3 µm bands based on the effect of difference-frequency generation (DFG). The mid-IR transmitter effectively generates up to 12 optical channels ranging from 3.5768 µm to 3.5885 µm with a power of 6.6 dBm, and each channel carries 12.5 Gbps binary phase shift keying (BPSK) modulated data. The mid-IR receiver regenerates the 1.5 µm band DWDM signal with a power of -32.1 dBm. Relevant results of regenerated signal demodulation have been collected in detail, including bit error ratio (BER), constellation diagram, and eye diagram. The power penalties of the 6th to 8th channels selected from the regenerated signal are lower than 2.2 dB compared with back-to-back (BTB) DWDM signal at a bit error ratio (BER) of 1E-6, and other channels can also achieve good transmission quality. It is expected to further push the data capacity to the terabit-per-second level by adding more 1.5 µm band laser sources and using wider-bandwidth chirped nonlinear crystals.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.487668DOI Listing

Publication Analysis

Top Keywords

15 µm band
16
150 gbps
8
fso transmission
8
3 µm band
8
mid-ir transmitter
8
dwdm signal
8
regenerated signal
8
bit error
8
error ratio
8
ratio ber
8

Similar Publications

A potential replacement that alleviates the shortcomings of the dominant light absorber materials used in solar photovoltaics has been synthesized, and its microstructural, electronic structure, and optical properties have been investigated. KCuS crystals were synthesized by the carbonate method. Transmission electron microscopy (TEM) established [010] as the growth direction of the needle-like monoclinic crystals.

View Article and Find Full Text PDF

To address the growing demand for compact and high-performance microwave filters in modern communication systems, a mixed-mode bandpass filter is proposed in the article. A dual-layer substrate integrated waveguide resonator loaded with a capacitive patch (CP-DSIWR) is proposed and theoretically analyzed, with both patch modes and cavity modes existing. To construct the bandpass filter, two rows of metallic vias are designed in the CP-SIWR to enable coupling between the two types of the modes, with the structure being fed by microstrip line.

View Article and Find Full Text PDF

We previously demonstrated the CFTR correctors VX-445 (elexacaftor) and S-VX-121 (vanzacaftor) potentiate heterologously-expressed BK channels, as well as in primary human bronchial epithelial cells (HBEs). This potentiation of BK resulted in altered vasoreactivity and neuronal excitability. We postulated novel compounds could be identified that would potentiate BK while not affecting CFTR.

View Article and Find Full Text PDF

Background: Barrett's esophagus (BE) is becoming increasingly prevalent in both Western countries and Japan. Early diagnosis of Barrett's neoplasia remains challenging. Traditionally, the Seattle protocol, a four-quadrant random biopsy method, has been recommended in Western guidelines.

View Article and Find Full Text PDF

Aortic and mitral valve repair in a child with rheumatic heart disease.

Multimed Man Cardiothorac Surg

September 2025

Department of Cardiothoracic Surgery, Royal Children’s Hospital, Melbourne, Australia

The patient had rheumatic heart disease, which resulted in severe aortic and mitral valve regurgitation. Repair of both valves was performed at 9 years of age. During surgery, the retracted aortic valve cusps required extension with bovine pericardial patches and suture reduction annuloplasty, and the mitral valve was repaired using a Cosgrove-Edwards (Edwards Lifesciences LLC, Irvine, CA) annuloplasty band.

View Article and Find Full Text PDF