Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Despite a plethora of studies conducted to date, researchers continue to investigate the best sealer and obturation technique combinations. The aim of this study is to compare the apical seal provided by two bioceramic sealers (Endoseal and Endosequence) with that provided by a calcium hydroxide sealer (Sealapex), and to evaluate the effect of different obturation techniques (cold lateral condensation, continuous wave compaction and single cone) on the apical seal under a stereomicroscope. A total of 110 single-rooted mandibular premolar teeth were decoronated, cleaned and shaped using the Endosequence filing system to tip size 30/0.04 taper. Canals were irrigated with 5.25% NaOCl and 17% EDTA. The samples were randomly divided into 11 groups (9 experimental and 2 control groups) according to the designated sealer and technique. Samples were stored in an incubator for 7 days at 37 °C under 100% humidity. Samples were coated with nail varnish except for apical 2 mm and vertically placed in 0.2% rhodamine B dye solution for 48 h. Samples were split longitudinally and viewed under a stereomicroscope at 40× magnification. Insignificant results were obtained between obturation techniques ( = 0.499) whereas statistically significant results were attained based on the type of endodontic sealer ( < 0.001). The overall lowest mean apical microleakage and best sealing ability was demonstrated by Sealapex (2.59 ± 1.20 mm) and amongst techniques by continuous wave compaction (3.90 ± 2.51 mm). Endosequence produced the best apical seal with the continuous wave compaction technique, whereas Endoseal did so with the bioceramic-coated single-cone technique. For the Sealapex sealer, the most effective apical seal was observed using cold lateral condensation. The quality and effectiveness of apical seal differed with the type of endodontic sealer and obturation technique used, and vice versa.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10051965 | PMC |
http://dx.doi.org/10.3390/medicina59030567 | DOI Listing |