98%
921
2 minutes
20
Background: Current intraocular pressure (IOP) measurements based on non-contact tonometry are derived from statistics-driven equations and lack biomechanical significance, which often leads to under-estimation in post-refractive surgery cornea. This study aims to introduce and validate modal analysis-derived intraocular pressure (mIOP) as a novel method generated through Legendre-based modal decomposition of the anterior corneal contour; it provides an accurate and intuitive IOP measurement from an energy-based perspective.
Methods: This retrospective study included 680 patients. Healthy participants were divided into reference (n = 385) and validation (n = 142) datasets, and the others underwent either femtosecond-assisted laser in situ keratomileusis (FS-LASIK, n = 58) or transepithelial photorefractive keratectomy (TPRK, n = 55). Corneal curvature of the right eyes was extracted from raw serial cross-sectional images of the cornea generated by Corvis ST, a noncontact tonometer with a high-speed Scheimpflug-camera. Legendre expansion was then applied to the corneal curvature to obtain the modal profiles (i.e., temporal changes of the coefficient for each basis polynomial [modes]). Using the reference dataset, feature selection on the modal profiles generated a final mIOP model consisting of a single parameter: total area under curve (frames 1-140) divided by the area under curve of the rising phase (frames 24-40) in the fourth mode, i.e. the M ratio. Validation was performed in both the healthy validation and postoperative datasets. IOP-Corvis, pachymetry-corrected IOP, biomechanically corrected IOP, and mIOP values were compared. For the FS-LASIK and TPRK groups, pairwise postoperative IOP changes were analyzed through repeated measures analysis of variance, and agreement was examined through Bland-Altman analysis. Using a finite element analysis based three-dimensional model of the human cornea, we further compared the M ratio with the true intraocular pressure within the physiological range.
Results: The M ratio-based mIOP demonstrated weak to negligible association with age, radius of corneal curvature, and central corneal thickness (CCT) in all validation analyses, and performed comparably with biomechanically corrected IOP (bIOP) in the refractive surgery groups. Both remained nearly constant postoperatively and were not influenced by CCT changes. Additionally, M ratio accurately represented true intraocular pressure in the in silico model.
Conclusions: mIOP is a reliable IOP measurement in healthy and postrefractive surgery populations. This energy-based, ratio-derived approach effectively filters out pathological, rotational, misaligned movements and serves as an interpatient self-calibration index. Modal analysis of corneal deformation dynamics provides novel insights into regional corneal responses against pressure loading.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10041475 | PMC |
http://dx.doi.org/10.1186/s12886-023-02867-8 | DOI Listing |
Ophthalmol Glaucoma
September 2025
Department of Ophthalmology and Visual Sciences, University of Michigan W.K. Kellogg Eye Center, Ann Arbor, Michigan. Electronic address:
Purpose: To investigate hand function and eye drop instillation success in adults with and without glaucoma.
Design: Cross-sectional pilot study.
Subjects: Adults aged ≥ 65 years with glaucoma who use eye drops daily and adults aged 65+ without glaucoma who do not regularly use eye drops.
Clin Exp Ophthalmol
September 2025
Department of Neurosurgery, National Neuroscience Institute, Singapore, Singapore.
Background: To describe clinical features, risk factors and outcomes of out-of-the-bag (OTB) intraocular lens (IOL) dislocation in dead bag syndrome (DBS).
Methods: Retrospective review of a single-surgeon series of eyes with IOLs that developed OTB IOL dislocation, managed at Singapore National Eye Centre (January 2014-December 2021), with a minimum of 6 months of follow-up. Eyes with OTB IOL dislocation following secondary IOL implantation and intraoperative capsule complications were excluded.
Acta Ophthalmol
September 2025
Department of Clinical Neuroscience, Institute of Neuroscience and Physiology, University of Gothenburg, Gothenburg, Sweden.
Purpose: To evaluate visual, anatomical and safety outcomes of aflibercept 8 mg in previously treated patients with neovascular age-related macular degeneration (nAMD).
Methods: This retrospective study included nAMD patients switched to aflibercept 8 mg from prior anti-VEGF therapies at Sahlgrenska University Hospital between February 2024 and February 2025. Data on best-corrected visual acuity (BCVA), central retinal thickness (CRT), pigment epithelial detachment (PED) height, fluid status, treatment intervals, time to fluid recurrence and adverse events were collected.
Zhonghua Yan Ke Za Zhi
September 2025
Beijing Aier-Intech Eye Hospital, Beijing 100021, China.
Two patients (a 7-year-old female and a 61-year-old male) had poor intraocular pressure control after XEN gel stent implantation. During the process of filtering bleb repair, the XEN gel implant retreated into the anterior chamber, and the limbal and corneal incisions were made. After the implant in the anterior chamber was taken out, it was implanted into the anterior chamber again from the original scleral tunnel for the female patient, while it was re-punctured into the anterior chamber with a 1-ml syringe needle at another site for the male patient.
View Article and Find Full Text PDFZhonghua Yan Ke Za Zhi
September 2025
The prevalence of normal tension glaucoma (NTG) in China stands at 1%. The inappropriate demarcation of normal intraocular pressure values may lead to misdiagnosis. The Glaucoma Group of Ophthalmology Branch of Chinese Medical Association released the consensus on the diagnosis and treatment of NTG in 2019, which established important clinical guidelines for the NTG management.
View Article and Find Full Text PDF