Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Operando powder X-ray diffraction (PXRD) is a widely employed method for the investigation of structural evolution and phase transitions in electrodes for rechargeable batteries. Due to the advantages of high brilliance and high X-ray energies, the experiments are often carried out at synchrotron facilities. It is known that the X-ray exposure can cause beam damage in the battery cell, resulting in hindrance of the electrochemical reaction. This study investigates the extent of X-ray beam damage during operando PXRD synchrotron experiments on battery materials with varying X-ray energies, amount of X-ray exposure and battery cell chemistries. Battery cells were exposed to 15, 25 or 35 keV X-rays (with varying dose) during charge or discharge in a battery test cell specially designed for operando experiments. The observed beam damage was probed by µPXRD mapping of the electrodes recovered from the operando battery cell after charge/discharge. The investigation reveals that the beam damage depends strongly on both the X-ray energy and the amount of exposure, and that it also depends strongly on the cell chemistry, i.e. the chemical composition of the electrode.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10161878PMC
http://dx.doi.org/10.1107/S160057752300142XDOI Listing

Publication Analysis

Top Keywords

beam damage
20
battery cell
12
damage operando
8
x-ray
8
x-ray diffraction
8
x-ray energies
8
x-ray exposure
8
battery
6
beam
5
operando
5

Similar Publications

A case report and literature analysis of a rare nonossifying fibroma of the mandible.

Medicine (Baltimore)

September 2025

Department of Medical Imaging, Central Laboratory of Jinan Stomatological Hospital, Jinan Key Laboratory of Oral Tissue Regeneration, Jinan, Shandong Province, China.

Abstract Rationale: Nonossifying fibroma (NOF) is one of the benign bone tumors in adolescents, and it rarely occurs in the jawbone. According to the site of onset, it is divided into the cortical type and the medullary type. Currently, there is no case report of medullary NOF in the mandible of the elderly.

View Article and Find Full Text PDF

Human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) are an important resource for identifying novel therapeutic targets and cardioprotective drugs. However, a key limitation of iPSC-CMs is their immature, fetal-like phenotype. Cultivation of iPSC-CMs in lipid-supplemented maturation media (MM) enhances the structural, metabolic and electrophysiological properties of iPSC-CMs.

View Article and Find Full Text PDF

The Power of Precision: Unravelling the Radiobiology of Targeted Radionuclide Therapy.

Clin Oncol (R Coll Radiol)

August 2025

School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom. Electronic address:

Targeted radionuclide therapy (TRT) involves systemic administration of a radionuclide attached to a cancer-targeting moiety. It has been proven to be a promising approach for primary cancer and metastasis treatment with minimal damage to surrounding tissues. TRT integrates the precision of molecular targeting with the therapeutic efficacy of radiation.

View Article and Find Full Text PDF

The effect of adding Na and Mg metal ions on soft X-ray induced photochemistry (SXIP) is investigated. To that aim, the soft X-ray beam of the METROLOGIE beamline at the SOLEIL synchrotron was extracted through air to irradiate solutions circulating in a microfluidic cell. Benzoate was used as a sensitive profluorescent probe for hydroxyl radicals.

View Article and Find Full Text PDF

Background And Purpose: Reducing the dose rate enhances efficacy in radiation therapy by allowing increased repair of sub-lethal damage. Pulsed low-dose radiation therapy (PLDR) is an innovative approach that is safe and effective for the reirradiation of recurrent gliomas and radioresistant tumors. In this study, the accuracy of the low dose rate volumetric modulated arc therapy (VMAT) delivery is tested in an Elekta Versa HD linear accelerator (linac) for delivering PLDR.

View Article and Find Full Text PDF