The success of non-operative management in trauma increased with the availability of new-generation CT scan machines, endoscopy, and angiography, becoming the standard of care in hemodynamically stable trauma patients with abdominal solid organ injuries, with a success rate of 78% to 98%. Post-traumatic pseudoaneurysms (PAs) can develop at any region of an injured artery and they may cause delayed bleeding in splenic or hepatic trauma, with an incidence in patients treated with NOM of 2%-27% and 1.2%-6.1% respectively. Diagnosis is made by angiography, contrast-enhanced computer tomography (CT), or Doppler Ultrasound (US) while the use of contrast-enhanced ultrasound (CEUS), has increased in recent years although few data are available about CEUS feasibility in the follow-up setting. The PseaAn study has been designed to assess the role of CEUS in the follow-up of abdominal trauma by defining its sensitivity, specificity and predictive values compared with abdominal CT scan. The PseAn study is a multi-centric international diagnostic cross-sectional study initiated by the Level I Trauma Center of the Niguarda Ca' Granda Hospital in Milan, Italy. To study the role of CEUS in detecting post-traumatic splenic, hepatic, and renal PAs compared with the gold standard of CT with intravenous contrast at different follow-up time points, and whether it can replace CT scan in the follow-up of solid organ injuries, patients with OIS III and above will undergo a follow-up with both a CEUS and CT scan to detect post-traumatic parenchymal pseudoaneurysm within two to five days from injury. The use of CEUS in the follow-up of abdominal trauma follow-up (particularly blunt trauma) has increased, to minimise the use of ionizing radiation and contrast media and encouraging results have been published during the last decade showing that CEUS is an accurate technique for evaluating traumatic lesions of solid abdominal organs. Conclusions We think that CEUS, which is underused worldwide, is a useful and safe tool that may replace CT scan in follow-up with the major advantage of reduced radiation. Our current study may give stronger evidence to support this view.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9986536 | PMC |
http://dx.doi.org/10.3389/fsurg.2023.1124087 | DOI Listing |
Int J Surg
September 2025
Department of Interventional Ultrasound, Fifth Medical Center of Chinese PLA General Hospital, Beijing, China.
Sonazoid, a combined blood pool and Kupffer-cell agent, can be specifically phagocytosed by Kupffer cells in the liver, allowing lesion detection and characterization of focal liver lesions (FLLs) at the post-vascular phase apart from the vascular phase which is similar to that of other second-generation US contrast agents. Sonazoid CEUS is currently approved for use in some Asian countries. With the increasing use of Sonazoid CEUS for FLLs in clinical practice, developing consensus or guidelines to help standardize its use is required.
View Article and Find Full Text PDFRev Cardiovasc Med
August 2025
Department of Neurosciences, Institute of Human Anatomy, University of Padova, 35121 Padova, Italy.
Harlequin syndrome, also known as differential hypoxia (DH) or North-South syndrome, is a serious complication of femoro-femoral venoarterial extracorporeal membrane oxygenation (V-A ECMO). Moreover, Harlequin syndrome is caused by competing flows between the retrograde oxygenated ECMO output and the anterograde ejection of poorly oxygenated blood from the native heart. In the setting of impaired pulmonary gas exchange, the addition of an Impella device (ECPELLA configuration), although beneficial for ventricular unloading and hemodynamic support, may further exacerbate this competition and precipitate DH.
View Article and Find Full Text PDFCureus
August 2025
Radiology, Mohammed VI University Hospital, Tangier, MAR.
The hypertrophied column of Bertin (HCB) is a benign anatomical variant of the renal cortex that may mimic a neoplastic mass, particularly on ultrasound, potentially leading to unnecessary diagnostic or surgical interventions. We report the case of a nine-year-old girl in whom a renal lesion was incidentally discovered during follow-up imaging for a post-traumatic subcapsular hematoma. Renal ultrasound revealed an isoechoic mass in the mid-portion of the left kidney, extending into the renal sinus.
View Article and Find Full Text PDFFront Endocrinol (Lausanne)
September 2025
Department of Medical Ultrasound, Affiliated Hospital of Jiangsu University, Zhenjiang, China.
Background: Given the challenge in preoperative diagnosis of high-volume lymph node metastasis (HVLNM) in clinical practice, we constructed and externally validated a comprehensive predictive model that integrated conventional ultrasound characteristics, contrast-enhanced ultrasound (CEUS) parameters, BRAFmutation, and clinicopathological data for HVLNM in clinically lymph node-negative (cN0) papillary thyroid carcinoma (PTC).
Methods: Totally, 126 clinically lymph node-negative (cN0) PTC patients who underwent subtotal or total thyroidectomy and accompanied with prophylactic cervical lymph node dissection between December 2022 and December 2024 were enrolled in this retrospective study, and an additional 47 cN0 PTC patients included for the external validation cohort. Univariate and multivariate analysis were performed to identify the independent risk factors for HVLNM, and a binary logistic regression equation and relevant nomogram was constructed to predict the risk about HVLNM.
Head Neck
September 2025
Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Zu Berlin, and Berlin Institute of Health, Berlin, Germany.
Background: Accurate preoperative differentiation of parotid gland tumors (PGTs) is essential for facial nerve preservation. This study evaluates a novel, real-time multiparametric ultrasound (mpUS) approach combining B-mode, shear wave elastography (SWE), and contrast-enhanced ultrasound (CEUS), based on qualitative image interpretation.
Methods: Eighty-nine patients with 91 PGTs underwent mpUS prior to surgery or ultrasound-guided biopsy.