Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: To evaluate the efficacy and safety of novel plasma radio frequency generator and its single-use polypectomy snares for endoscopic mucosal resection (EMR) of gastrointestinal (GI) polyps.
Methods: A total of 217 patients with 413 GI polyps were recruited from four centers in China. Patients were assigned to experimental or control groups using a central randomization method. The experimental group used the novel plasma radio frequency generator and its matched single-use polypectomy snares (Neowing, Shanghai), while the control group used the high-frequency electrosurgical unit (Erbe, Germany) and disposable electrosurgical snares (Olympus, Japan). The primary endpoint was the en bloc resection rate, and the non-inferiority margin was set at 10%. Secondary endpoint included operation time, coagulation success rate, intraoperative and postoperative bleeding rate, and perforation rate.
Results: The en bloc resection rate was 97.20% (104/107) in the experimental group and 95.45% (105/110) in the control group (P = 0.496). The operation time was 29.14 ± 20.21 min in the experimental group and 30.26 ± 18.74 min in the control group (P = 0.671). The average removal time of a single polyp in the experimental group was 7.52 ± 4.45 min, which was slightly shorter than that in the control group 8.90 ± 6.67 min, with no statistical difference (P = 0.076). The intraoperative bleeding rates of the experimental group and control group were 8.41% (9/107) and 10.00% (11/110), respectively (P = 0.686). No intraoperative perforation occurred in either group. The postoperative bleeding rates of the experimental group and the control group were 1.87% (2/107) and 4.55% (5/110), respectively (P = 0.465). No postoperative perforation occurred in the experimental group (0/107), while one case of delayed perforation occurred in the control group (1/110, 0.91%). There was no statistical difference between the two groups.
Conclusions: Endoscopic mucosal resection of GI polyps with the novel plasma radio frequency generator is safe and effective, and non-inferior to the conventional high-frequency electrosurgical system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00464-023-09945-4 | DOI Listing |