98%
921
2 minutes
20
The implantation of cardiac implantable electronic devices (CIEDs) may result in or worsen previously existing tricuspid regurgitation (TR). The prevelence of lead-related tricuspid regurgitation (LRTR) in patients with CIEDs is between 7.2% and 44.7% when the degree of worsening TR is not reported, or from 9.8% and 38% when it is diagnosed as worsening of TR severity by at least 2 grades after a CIED has been implanted. It has been suggested that a CIED lead positioned over or pinning a leaflet may be the main cause of TR in this patient population. The septal and posterior leaflets of the tricuspid valve have been reported to be the most affected by CIED leads. Severe LRTR is related to the development of heart failure (HF) or worsening of previously existing dysfunction; it is also associated with elevated mortality. However, there are no definitive predictors of LRTR development or standardized methods of treatment. Some studies have suggested that imaging-guided lead placement can reduce the occurrence of LRTR. This review summarizes current knowledge concerning the development, evaluation, consequences, and management of LRTR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.17219/acem/159531 | DOI Listing |
JACC Cardiovasc Interv
September 2025
Structural Heart & Valve Center, Houston Heart, HCA Houston Healthcare Medical Center, Houston, Texas, USA. Electronic address:
Struct Heart
September 2025
The Carl and Edyth Lindner Research Center at the Christ Hospital, Cincinnati, Ohio, USA.
Severe, untreated tricuspid regurgitation is associated with worse clinical outcomes. While isolated tricuspid valve (TV) surgery has been linked to poor long-term outcomes, transcatheter TV therapies, including edge-to-edge repair and transcatheter tricuspid valve replacement (TTVR), have emerged as effective alternatives and have been shown to improve outcomes, leading to their regulatory approval in the United States. Conduction system abnormalities are commonly seen among patients undergoing TTVR due to the close proximity of the atrioventricular node and the His bundle to the TV annulus.
View Article and Find Full Text PDFFront Cardiovasc Med
August 2025
First Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Aim: To assess the incremental value of real-time three-dimensional (3D) transesophageal echocardiography (TEE) in visualizing tricuspid valve (TV) anatomy for procedural planning and guidance of transcatheter edge-to-edge repair (TEER) in cases of severe tricuspid regurgitation (TR).
Materials And Methods: An observational study was conducted on 54 patients with severe TR. The visualization of the TV leaflets during systole was graded semiquantitatively using predefined criteria: 0 points-no visible leaflet border or tissue; 1.
Heart Rhythm O2
August 2025
Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland.
J Thorac Cardiovasc Surg
September 2025
Division of Cardiac, Thoracic & Vascular Surgery, Department of Surgery, Columbia University Irving Medical Center, NewYork-Presbyterian Hospital, New York, NY. Electronic address:
Objective: Our objective was to determine the long-term outcomes of concomitant tricuspid valve procedures (TVP) during continuous-flow left ventricular assist device (LVAD) implantation.
Methods: We retrospectively reviewed patients who received HeartMate II or 3 from 2004 to 2023. Nine patients who had a previous TVP were excluded.