Background: This report describes the findings of the 2020 Italian Catheter Ablation Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC).
Methods: Data collection was retrospective. A standardized questionnaire was completed by each of the participating centers.
Results: A total of 10 378 ablation procedures were performed by 66 institutions. Most centers (70%) have an electrophysiology laboratory, and 23% a hybrid cardiac surgery laboratory. All centers have a 3D mapping system. The median number of electrophysiologists and nurses involved in the electrophysiology laboratory was 3.5 and 3, respectively. An electrophysiology technician was involved in 35% of all centers. In 88.2% of cases, catheter ablation was performed for supraventricular arrhythmias; the most frequently treated arrhythmia was atrial fibrillation (39.4%), followed by atrioventricular nodal reentrant tachycardia (18.6%), and common atrial flutter (10.6%). In 72.9% of patients, catheter ablation was performed using a 3D mapping system, with a "near-zero" fluoroscopic approach in 37.7% of all patients.
Conclusions: The 2020 Italian Catheter Ablation Registry confirmed that the electrophysiology activity was markedly affected by the COVID-19 pandemic; atrial fibrillation is the most frequently treated arrhythmia with an increasing number of procedures performed with a 3D mapping system and a "near-zero" approach.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1714/3980.39628 | DOI Listing |
J Interv Card Electrophysiol
September 2025
Cardiac Ablation Solutions, Medtronic, Minneapolis, MN, USA.
Background: Catheter ablation is beneficial in patients with symptomatic persistent atrial fibrillation (PerAF), and pulsed field ablation (PFA) is a promising energy source to safely and durably create ablation lesions. However, catheter-specific "PFA waveforms and designs" result in effectiveness and safety profiles that are not transferable to other PFA technologies. A head-to-head comparison between the dual-energy, wide-footprint lattice-tip (Sphere-9, Medtronic) and pentaspline PFA catheter (Farawave, Boston Scientific) is not yet available.
View Article and Find Full Text PDFJACC Case Rep
September 2025
Department of Cardiovascular Medicine, Okayama University Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan.
Background: The rotational atherectomy system can effectively debulk calcified coronary lesions. However, rare complications specific to that system have been reported.
Case Summary: A 77-year-old man with a heavily calcified lesion in the right coronary artery (RCA) ostium underwent percutaneous coronary intervention in an 8-F system.
Kardiologiia
September 2025
Bakulev National Medical Research Cener for Cardiovascular Surgery.
Aim To compare the long-term effectiveness of cryoballoon ablation (CBA) and radiofrequency ablation (RFA) in patients with atrial fibrillation (AF).Material and methods This retrospective single-site study included 597 patients with AF who had undergone CBA (n=241) or RFA (n=356) between 2016 and 2024. The study participants included 355 men (59.
View Article and Find Full Text PDFMed Phys
September 2025
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, P.R. China.
Background: In catheter-based radiofrequency ablation (RFA), energy is delivered to heterogeneous thin-walled tissues to induce therapeutic heating. Variations in electrical and mechanical properties of tissue contents have a great effect on outcomes.
Purpose: The objective of this study is to develop models that replicate tissue heterogeneity and visualize ablation zones for effective evaluation and optimization.
J Cardiovasc Electrophysiol
September 2025
Demoulas Center for Cardiac Arrhythmias, Massachusetts General Hospital, Boston, Massachusetts, USA.
Introduction: Fluoroless mapping and ablation using a Pentaspline pulsed field ablation catheter has many advantages. This can be achieved using a "tripolar configuration," which enables high-quality electroanatomical maps, improves the ability to localize electrograms (EGMs), and minimizes the use of additional mapping catheters compared to the standard bipolar configuration. We aimed to evaluate the benefits of using a tripolar configuration in fluoroless atrial fibrillation ablation compared to the standard bipolar configuration.
View Article and Find Full Text PDF