Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

: To prevent postoperative problems in extreme lateral interbody fusion (XLIF), it is critical that the vertebral endplate not be injured. Unintentional endplate injuries may depend on the cage. A novel porous titanium cage for XLIF has improved geometry with a tapered tip and smooth surface. We hypothesized that this new cage should lead to fewer endplate injuries. : This retrospective study included 32 patients (mean 74.1 ± 6.7 years, 22 females) who underwent anterior and posterior combined surgery with XLIF for lumbar degenerative disease or adult spinal deformity from January 2018 to June 2022. A tapered 3D porous titanium cage (3DTi; 11 patients) and a squared PEEK cage (sPEEK; 21 patients) were used. Spinal alignment values were measured on X-ray images. Vertebral endplate concavity (VEC) was defined as concavity ≥ 1 mm of the endplate on computed tomography (CT) images, which were evaluated preoperatively and at 1 week and 3 months postoperatively. : There were no significant differences in the patient demographic data and preoperative and 3-month postoperative spinal alignments between the groups. A 3DTi was used for 25 levels and an sPEEK was used for 38 levels. Preoperative local lordotic angles were 4.3° for 3DTi vs. 4.7° for sPEEK ( = 0.90), which were corrected to 12.3° and 9.1° ( = 0.029), respectively. At 3 months postoperatively, the angles were 11.6° for 3DTi and 8.2° for sPEEK ( = 0.013). VEC was present in 2 levels (8.0%) for 3DTi vs. 17 levels (45%) for sPEEK ( = 0.002). After 3 months postoperatively, none of the 3DTi had VEC progression; however, eight (21%) levels in sPEEK showed VEC progression ( = 0.019). : The novel 3DTi cage reduced endplate injuries by reducing the endplate load during cage insertion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967078PMC
http://dx.doi.org/10.3390/medicina59020372DOI Listing

Publication Analysis

Top Keywords

vertebral endplate
12
porous titanium
12
titanium cage
12
endplate injuries
12
months postoperatively
12
cage
9
endplate concavity
8
interbody fusion
8
squared peek
8
peek cage
8

Similar Publications

Purpose: This study aims to validate the usefulness of T10-pelvic angle (T10PA) in predicting pelvic tilt (PT) restoration, proximal junctional kyphosis (PJK) development, and clinical outcomes after adult spinal deformity (ASD) surgery.

Methods: This retrospective study included 213 ASD patients who underwent fusion from the lower thoracic spine (T9 or T10) to the pelvis. T10PA was measured on 6-week postoperative radiographs as the angle between the center of T10 and the hip center, and from the hip center to the midpoint of the S1 upper endplate.

View Article and Find Full Text PDF

Objective: The aim of this study was to compare the predictive efficacy of quantitative CT (QCT)-based endplate volumetric bone mineral density (EP-vBMD) and MRI-based endplate vertebral bone quality (EBQ) score for cage subsidence (CS) after lateral lumbar interbody fusion (LLIF).

Methods: A retrospective study was conducted on patients who underwent single-level LLIF in conjunction with pedicle screw fixation at the authors' institution between January 2019 and April 2023. The volumetric bone mineral density (vBMD) was measured based on preoperative CT using phantom-less QCT software.

View Article and Find Full Text PDF

Study Design: Cross-sectional study.

Objective: This study aimed to analyze the failure patterns of expandable corpectomy cages.

Summary Of Background Data: Expandable corpectomy cages offer significant advantages for anterior column reconstruction but introduce unique mechanical complexities.

View Article and Find Full Text PDF

Study DesignProspective disease-oriented study.ObjectiveTo describe the MRI findings in patients with failed conservative treatment for degenerative lumbar diseases and to identify predictors of back pain intensity in these patients.MethodsWe analyzed demographic (sex, age) and clinical scale data as well as the lumbar MRI findings (Pfirrmann disc degeneration, Modic types, endplate defects, disc height and osteophytes) in RuDDS patients.

View Article and Find Full Text PDF

Background: Lumbar cartilage endplate (CEP) structures show low signal intensity on conventional magnetic resonance imaging (MRI), making them hard to observe and quantify. This often results in poor correlation between conventional MRI findings and low back pain (LBP) symptoms and provides inadequate guidance for clinical decisions.

Methods: The study included Twenty-five healthy volunteers and forty-one patients with LBP.

View Article and Find Full Text PDF