Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background Cortical multiple sclerosis lesions are clinically relevant but inconspicuous at conventional clinical MRI. Double inversion recovery (DIR) and phase-sensitive inversion recovery (PSIR) are more sensitive but often unavailable. In the past 2 years, artificial intelligence (AI) was used to generate DIR and PSIR from standard clinical sequences (eg, T1-weighted, T2-weighted, and fluid-attenuated inversion-recovery sequences), but multicenter validation is crucial for further implementation. Purpose To evaluate cortical and juxtacortical multiple sclerosis lesion detection for diagnostic and disease monitoring purposes on AI-generated DIR and PSIR images compared with MRI-acquired DIR and PSIR images in a multicenter setting. Materials and Methods Generative adversarial networks were used to generate AI-based DIR ( = 50) and PSIR ( = 43) images. The number of detected lesions between AI-generated images and MRI-acquired (reference) images was compared by randomized blinded scoring by seven readers (all with >10 years of experience in lesion assessment). Reliability was expressed as the intraclass correlation coefficient (ICC). Differences in lesion subtype were determined using Wilcoxon signed-rank tests. Results MRI scans of 202 patients with multiple sclerosis (mean age, 46 years ± 11 [SD]; 127 women) were retrospectively collected from seven centers (February 2020 to January 2021). In total, 1154 lesions were detected on AI-generated DIR images versus 855 on MRI-acquired DIR images (mean difference per reader, 35.0% ± 22.8; < .001). On AI-generated PSIR images, 803 lesions were detected versus 814 on MRI-acquired PSIR images (98.9% ± 19.4; = .87). Reliability was good for both DIR (ICC, 0.81) and PSIR (ICC, 0.75) across centers. Regionally, more juxtacortical lesions were detected on AI-generated DIR images than on MRI-acquired DIR images (495 [42.9%] vs 338 [39.5%]; < .001). On AI-generated PSIR images, fewer juxtacortical lesions were detected than on MRI-acquired PSIR images (232 [28.9%] vs 282 [34.6%]; = .02). Conclusion Artificial intelligence-generated double inversion-recovery and phase-sensitive inversion-recovery images performed well compared with their MRI-acquired counterparts and can be considered reliable in a multicenter setting, with good between-reader and between-center interpretative agreement. Published under a CC BY 4.0 license. See also the editorial by Zivadinov and Dwyer in this issue.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10102645PMC
http://dx.doi.org/10.1148/radiol.221425DOI Listing

Publication Analysis

Top Keywords

psir images
28
dir psir
20
ai-generated dir
16
multiple sclerosis
16
lesions detected
16
dir images
16
images
14
mri-acquired dir
12
dir
11
psir
11

Similar Publications

Aims: In acute ST-segment elevation myocardial infarction, ischaemia and reperfusion lead to a cascade of myocardial injury that can be characterized by cardiac magnetic resonance (CMR) imaging, including coagulation necrosis, oedema, papillary muscle damage, microvascular obstruction, and intramyocardial haemorrhage. Conventional CMR protocols require multiple sequences to be performed and complicated analysis. This study evaluates SPOT-MAPPING, a sequence that acquires co-registered T2 maps and dual bright- and black-blood late gadolinium enhancement (LGE) images in a single scan.

View Article and Find Full Text PDF

Background: Segmented phase-sensitive inversion recovery (PSIR) turbo fast low-angle shot (FLASH) has become the reference standard sequence for late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging. However, it has a long scanning time, requires multiple breath holds, and is prone to motion artifacts. This study aimed to compare the accuracy of two fast LGE sequences with FLASH PSIR in acute myocardial infarction (AMI) detection and quantification of LGE.

View Article and Find Full Text PDF

Background: Diagnosing transthyretin-related cardiac amyloidosis (ATTR-CA) relies on excluding plasma cell dyscrasia and performing bone-avid tracer cardiac scintigraphy. However, visual assessment of cardiac uptake has limitations in evaluating amyloid burden. Whole-body single-photon emission computed tomography-computed tomography (SPECT-CT) may overcome these limitations by enabling quantitative assessment, but data on test-retest reproducibility are lacking.

View Article and Find Full Text PDF

Multiple sclerosis (MS) is an autoimmune neuroinflammatory disorder affecting the central nervous system (CNS). It is primarily driven by an immune-mediated inflammatory response, leading to the demyelination of neurons. Neuroimaging, particularly magnetic resonance imaging (MRI), plays a crucial role in diagnosing, monitoring, and predicting the progression of MS.

View Article and Find Full Text PDF

Improved and Automated Detection of Papillary Muscle Infarction Using Joint Bright- and Black-Blood Late Gadolinium Enhancement MRI.

J Magn Reson Imaging

September 2025

IHU LIRYC, Electrophysiology and Heart Modeling Institute, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Université de Bordeaux, Pessac, France.

Background: Papillary muscle infarction (PMI) has been linked to significantly increased mortality and is associated with ventricular arrhythmias and mitral regurgitation. Reference bright-blood late gadolinium enhancement (LGE) imaging provides poor scar-to-blood contrast, making PMI visualization challenging. Black-blood LGE imaging overcomes this limitation by improving the blood-scar contrast.

View Article and Find Full Text PDF