Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Studies comparing the use of total hip arthroplasty (THA) with conventional implants and hemiarthroplasty for displaced femoral neck fractures (DFNF) have reported better patient satisfaction scores and outcomes in the former, but also significant dislocation rates (6.9-13%).The total hip arthroplasty with dual mobility cup (THA-DMC) design is mechanically proven to increase the hip range of motion and jump distance to dislocation relative to conventional implants. Despite its potential benefit, clinical studies analyzing the use of THA-DMC in the treatment of DFNF in comparison to conventional THA within the Asian population are still limited. Our study aims to compare the rate of complications and functional outcomes between the 2 implants in the treatment of DFNF.

Materials And Methods: This was a retrospective cohort study conducted in a single tertiary care institution. From January 2015 to May 2020, data from 129 consecutive patients who satisfied the inclusion criteria and underwent either a THA or THA-DMC for DFNF were collected and divided into 2 groups. All patients received a standardized post-operative treatment and follow-up regime. Both groups of patients were assessed for post-operative complications such as dislocation, peri-prosthetic fractures, surgical site infections, medical complications. Their functional outcomes as well as patient-reported outcome scores were also assessed via the SF-36 score and Oxford hip score questionnaires at 6 months and 1 year.

Results: A total of 42 patients with dual mobility implants and 87 patients with conventional implants were recruited. There was no dislocation in the THA-DMC group while there were 4 cases (4/87, 4.6%) of dislocation in the THA group. Regarding post-operative function, both groups had comparable functional outcomes. There were no statistically significant differences between the patient-reported outcome scores (Oxford hip score and SF-36) at 6 months and 1 year.

Conclusion: We report promising short-term outcomes utilizing dual mobility implants in total hip arthroplasty for the treatment of DFNFs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9789225PMC
http://dx.doi.org/10.1007/s43465-022-00759-5DOI Listing

Publication Analysis

Top Keywords

total hip
16
hip arthroplasty
16
dual mobility
16
conventional implants
16
functional outcomes
12
utilizing dual
8
complications functional
8
groups patients
8
patient-reported outcome
8
outcome scores
8

Similar Publications

Background: We retrospectively evaluated the efficacy of using additional obesity management medications (OMMs) within the first year after undergoing laparoscopic sleeve gastrectomy (LSG).

Methods: We retrospectively analyzed 246 patients who underwent primary LSG in our institution and were followed up for at least 12 months. We collected body weights preoperatively and at three, six, 12, and 24 months postoperatively, along with body composition and laboratory results preoperatively and at 12 months.

View Article and Find Full Text PDF

Background And Objective: With obese individuals experiencing osteoarthritis (OA) at early stages of life, hip resurfacing (HR) has emerged as an alternative to arthroplasty. The purpose is to conduct a short-term analysis on patients with obesity who underwent primary HR for OA compared to a benchmark control group of non-obese patients.

Materials And Methods: Patients with a body mass index (BMI) ≥ 30 kg/m2 who underwent HR from 2010 to 2021 were eligible for inclusion.

View Article and Find Full Text PDF

Objectives: This study evaluated the effects of proximal core training on biomechanical risk factors and strength parameters in individuals at high risk of anterior cruciate ligament (ACL) injury (specifically: those exhibiting pathological movement patterns, neuromuscular deficits or biomechanical risk factors) and compared direct versus indirect interventions. We hypothesised that targeted training enhances dynamic knee stabilisation and hip control during high-risk manoeuvres, with direct approaches providing superior biomechanical benefits through neuromuscular control optimisation.

Design: Systematic review and meta-analysis using the Grading of Recommendation, Assessment, Development and Evaluation (GRADE) approach.

View Article and Find Full Text PDF

Background: Individuals who have had total joint arthroplasty (TJA) are subject to lifelong exposure to metal-based implants. The relationship between chronic exposure to metal-based implants and systemic effects on the brain remains unclear. We aimed to determine the association between TJA and the subsequent long-term risk of dementia.

View Article and Find Full Text PDF

Introduction: Total hip arthroplasty (THA) with third-generation alumina ceramic heads on highly cross-linked polyethylene liners (HXLPE) has demonstrated excellent outcomes in young patients. However, concerns of ceramic head fracture, squeaking, stripe wear, and limited sizing led to the development of a fourth-generation ceramic head. The purpose of our study was to report on survivorship, wear characteristics, and patient-reported outcomes of THA with a fourth-generation 32-mm ceramic femoral head and HXLPE liner in patients 50 years or younger at 10-year minimum follow-up.

View Article and Find Full Text PDF