A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy. | LitMetric

Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy.

Eur J Med Res

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, 1 Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.

Published: January 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To compare the accuracy of three intraocular lens (IOL) formulas in Chinese cataract patients with prior radial keratotomy (RK).

Methods: Medical records of cataract patients with prior RK at Beijing Tongren Hospital were retrospectively analysed. The absolute error (AE) was calculated as the absolute difference between the actual postoperative spherical equivalent and the predicted spherical equivalent. The AE and percentages of eyes with AE within 0.5D, 1.0D, and 2.0D for three formulas [Barrett True-K, Holladay 1 (D-K), Haigis] were calculated and compared.

Results: Forty-seven eyes of 28 cataract patients were included. The Median AE (MedAE) was significantly different among the three formulas (P < 0.001). The MedAE was lowest for the Barrett True-K formula (0.62), followed by the Haigis (0.76), and Holladay 1 (D-K) (1.16). The percentages of eyes with AE within 0.5D, and 1.0D were significantly different among the 3 formulas (P = 0.009, and P < 0.001). The Barrett True-K formula achieved the highest percentages (46.8%) of eyes with AE within 0.5D. Haigis achieved the highest percentages (70.21%) of eyes with AE within 1.0 D.

Conclusions: Barrett True-K is the most accurate IOL power calculation formula among the 3 formulas and Haigis is an alternative choice. Considering the relatively lower accuracy of IOL formulas in cataract patients with prior RK, newer and more accurate IOL formulas are desirable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9832763PMC
http://dx.doi.org/10.1186/s40001-023-00998-8DOI Listing