Purpose: This study aimed to compare the marginal and internal fit of five-unit zirconia-based fixed dental prostheses (FDPs) fabricated using digital scans and conventional impressions.

Materials And Methods: Nine master models with three zirconia abutments were scanned with an intraoral scanner (test group), and nine conventional impressions (control group) of these same models were also made. The stone casts from these impressions were scanned with a laboratory extraoral scanner (D700, 3Shape, Copenhagen, Denmark). A total of 18 five-unit zirconia-based FDP frameworks (test group, n = 9; control group, n = 9) were manufactured. Marginal and internal fit (in μm) were evaluated using the replica method under micro-computed tomography. Analysis of variance (one-way ANOVA) and Kruskal-Wallis tests were used to compare continuous variables across two groups. A level of p < 0.05 was accepted as statistically significant.

Results: The mean ± standard deviation of the marginal fit was 95.03 ± 12.74 μm in the test group and 106.02 ± 14.51 μm in the control group. The lowest marginal mean value was observed in the test group, with a statistically significant difference compared to the control group (F = 14.56, p < 0.05). The mean ± standard deviation of the internal fit was 103.61 ± 9.32 and 106.38 ± 7.64 μm, respectively, in the test and control groups, with no statistically significant difference (F = 1.56, p > 0.05). The mean values of both groups were clinically acceptable.

Conclusions: The five-unit zirconia-based FDPs fabricated with digital scans showed better fit than those in the conventional impression group. Within the limitations of this study, these results are encouraging, and continued progress in the digital field should allow for more accurate long-span restorations.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.13639DOI Listing

Publication Analysis

Top Keywords

marginal internal
12
internal fit
12
five-unit zirconia-based
12
fit five-unit
8
zirconia-based fixed
8
fixed dental
8
dental prostheses
8
fabricated digital
8
digital scans
8
scans conventional
8

Similar Publications

Purpose: Esophageal RV25 < 20 % and AV35 < 0.27 mL were reported as dose constraints predictive of grade ≥ 2 radiation esophagitis (RE) for breast cancer in our previous study. This prospective study aimed to validate the effectiveness of esophageal dose constraints and develop RE prediction models.

View Article and Find Full Text PDF

Purpose: Designing restorations remains challenging because the process is time-consuming and requires operator skill and experience. This clinical study evaluated the fit accuracy of polymerized complete crowns fabricated using a web-based 3D generative artificial intelligence design (GAID) method compared to crowns fabricated using a conventional computer-aided design (CCAD) method.

Materials And Methods: Sixty-two patients requiring complete crowns in maxillary and mandibular premolars and molars were enrolled.

View Article and Find Full Text PDF

Background: The gut microbiota plays a vital role in various physiological processes, including metabolism. Fecal microbiota transplantation (FMT) involves transferring fecal matter from a healthy donor to rebalance a patient's intestinal dysbiosis. The impact of FMT on metabolic syndrome (MetS) is subject to debate.

View Article and Find Full Text PDF

Background: Neoadjuvant chemotherapy (NACT) is used to reduce breast cancer size before surgery, allowing for breast conservation surgery (BCS) instead of mastectomy. However, concerns exist about higher positive margins and local recurrence rates.

Aims: This study compared the incidence of positive margins, local recurrence rates, and other oncologic outcomes of BCS performed either upfront or after NACT.

View Article and Find Full Text PDF

Background: Guidelines recommend leaving in situ rectosigmoid polyps diagnosed during colonoscopy that are 5 mm or smaller if the endoscopist optically predicts them to be non-neoplastic. However, no randomised controlled trial has been done to examine the efficacy and safety of this strategy.

Methods: This open-label, multicentre, non-inferiority, randomised controlled trial enrolled adults age 18 years or older undergoing colonoscopy for screening, surveillance, or clinical indications across four Italian centres.

View Article and Find Full Text PDF