A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Silica-based mesoporous ion-imprinted fluorescent sensors for the detection of Pbin aqueous environments. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this work, an environment-friendly core-shell material based on CDs@SiOas the core and mesoporous ion-imprinted layer as the shell was reported. As a highly sensitive and accurate fluorescent sensor for the detection of Pbin environmental water, the composition combined ion imprinting technology with quantum dots to selectively quench the fluorescence of CDs by metal coordination in the presence of Pb, and the visual change of gradually weakening blue color could be observed by the naked eye for visual detection. The mesoporous structure significantly improved the detection recognition rate of CDs@SiO@MIIPs.The molecularly imprinted sensor presented a favorable linear relationship over a Pbconcentration range from 10 nmol lto 100 nmol land a detection limit of 2.16 nmol lfor Pb. The imprinting factor of the CDs@SiO@MIIPs was 5.13. The sensor has a fast detection rate, is highly selective in the identification of Pb, and can be reused up to 10 times. The applicability of the method was evaluated by the determination of Pbin spiked environmental water samples with satisfactory results.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6528/aca76dDOI Listing

Publication Analysis

Top Keywords

mesoporous ion-imprinted
8
detection pbin
8
environmental water
8
detection
6
silica-based mesoporous
4
ion-imprinted fluorescent
4
fluorescent sensors
4
sensors detection
4
pbin aqueous
4
aqueous environments
4

Similar Publications