A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Ion Addition by Electrolysis to Improve the Quantitative Analysis of Bacteria with MALDI-TOF MS. | LitMetric

Ion Addition by Electrolysis to Improve the Quantitative Analysis of Bacteria with MALDI-TOF MS.

Anal Chem

Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology (Ministry of Education), Tsinghua University, Beijing 100084, P. R. China.

Published: January 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is commonly applied to the identification of bacteria but rarely used for quantitative detection due to the inhomogeneous crystallization of the matrix leading to the unsatisfactory linear relationship between the sample amount and the mass spectrum signals. Herein, we proposed a noninterference ion addition (NIA) method by electrolysis to improve homogeneous crystallization during the evaporation progress of sample droplets on the target plates. The active metal wire was inserted in the droplet as the anode electrode, and metal ions were released through electrolysis. The directional migration of metal ions under the electric field can hinder the migration of matrix molecules to the boundary and homogenize the matrix crystals by forming spherical crystals. Simultaneously, trace cationic surfactant was added to the droplet for pinning the contact surface to define the circle crystallization region. The metal ions from the anode electrode wire were deposited on the surface of the target plates which served as the cathode. Therefore, ion addition has no interference effect on ionization during MALDI-MS detection. This NIA method benefits the homogeneous crystallization and so improves the quantitative analysis. NIA is suitable for biological samples with different matrices, and bacterial samples could be quantitatively analyzed.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.2c02813DOI Listing

Publication Analysis

Top Keywords

ion addition
12
metal ions
12
electrolysis improve
8
quantitative analysis
8
nia method
8
homogeneous crystallization
8
target plates
8
anode electrode
8
addition electrolysis
4
improve quantitative
4

Similar Publications