98%
921
2 minutes
20
The electro-cautery lumen apposing metal stent (EC-LAMS) is a newly developed device that integrates the electro-cautery cyctotome with the one-step metal stent delivery and releasing system in recent years. LAMS was first designed to complete the drainage of pancreatic fluid collection under endoscopic ultrasound guidance, and the technological innovation of EC-LAMS has made more off-labeled indications of endoscopic intervention for gastrointestinal diseases realized, such as abdominal fluid drainage, bile duct, or gallbladder drainage through stomach or duodenum, gastrointestinal anastomosis, and the establishment of fistulous channel for further endoscopic operation when necessary. The unique feature of this metal stent is that it has the design of a saddle shape and a large lumen, and can almost connect the adjacent structures to minimize the risk of perforation and leakage. Compared with traditional LAMS, EC-LAMS, an advanced integrated device, can greatly simplify the endoscopic process, shorten the procedure time and reduce the technical difficulty, thus it can help endoscopists complete more complex endoscopic interventions. In this review, we discuss the state of art with regard to EC-LAMS and its endoscopic process, current indications, outcomes, adverse events, and future application prospects.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9747751 | PMC |
http://dx.doi.org/10.3389/fmed.2022.1002031 | DOI Listing |
Gastrointest Endosc
September 2025
Gastroenterology and Digestive Endoscopy Unit, ASST Cremona, Cremona, Italy.
J Vasc Access
September 2025
National Yang Ming Chiao Tung University, Taipei, Taiwan.
Purpose: Although stent grafts have demonstrated significant benefits over bare metal stents and conventional venoplasty at maintaining patency of dialysis vascular access, they are far from perfect and are prone to edge stenosis. A new strategy of placing stent graft to reduce the possible occurrence of edge stenosis is therefore proposed in this study.
Materials And Methods: A retrospective review between 2015 and 2023 identified 21 arteriovenous grafts (AVG) hemodialysis patients who underwent stent graft placement with the medial stent end in an outflow venous valve.
Clin Gastroenterol Hepatol
September 2025
Unité d'Endoscopie Interventionnelle, Ramsay Santé, Hôpital Privé des Peupliers, Paris, France; Department of Clinical Medicine and Surgery, University of Naples "Federico II", Naples, Italy.
JACC Case Rep
September 2025
Seattle Children's Hospital, University of Washington, Seattle, Washington, USA.
Objective: To demonstrate a detailed procedural guide for right ventricular outflow tract (RVOT) stent placement for palliation of tetralogy of Fallot and pulmonary stenosis in a patient weighing <2 kg.
Key Steps: Obtain wire position with an 0.018-inch Hi-Torque floppy wire in a distal branch pulmonary artery.
Endoscopy
December 2025
Gastroenterology, Kanazawa University Hospital, Kanazawa, Japan.