Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: To determine the bonding effectiveness of experimental 2-step universal adhesives (UAs) to high C-factor class-I cavity-bottom dentin and to assess the potential bond-strength contribution of an additional flowable composite layer.

Methods: Three experimental 2-step UA formulations, involving the application of a 10-MDP-based primer followed by a hydrophobic adhesive resin with a 15-to-20-µm film thickness and differing only for filler, referred to as BZF-21 (silica and bioglass filler), BZF-29 (silica filler) and BZF-29_hv (higher silica-filler loading resulting in a higher viscosity), all prepared by GC, along with three representative commercial adhesives, Clearfil SE Bond 2 (C-SE2, Kuraray Noritake), G-Premio Bond (G-PrB, GC) and OptiBond FL (Opti-FL, Kerr), were comparatively investigated for their 'immediate' and 'aged' (50,000 thermocycles) micro-tensile bond strength (μTBS), when applied either in etch-and-rinse (E&R) or self-etch (SE) mode, to high C-factor class-I cavity-bottom dentin (n = 10; 10 experimental groups). Four additional experimental groups involved the extra application of the flowable composite G-ænial Universal Flo (GC), employed as an intermediate liner in combination with the adhesives BZF-29 and G-PrB and again applied both in E&R or SE mode. Statistical analysis was performed using linear mixed-effects (LME) modelling and linear regression analysis (p < 0.05).

Results: All 2-step UAs performed similarly when compared to the gold-standard E&R Opti-FL and SE C-SE2 adhesives, except for the aged μTBS of BZF-29_hv applied in E&R mode, and significantly outperformed the 1-step UA G-PrB. Significant reduction in μTBS upon aging was only recorded for 2-step UAs applied in E&R mode. The extra flowable composite layer significantly improved G-PrB's μTBS.

Significance: The experimental 2-step UAs revealed favorable bonding performance in the challenging high C-factor class-I cavity model, comparable to that of the multi-step gold-standard E&R and SE adhesives and superior to that of the 1-step UA investigated. An additionally applied flowable composite layer compensated for the lower bonding effectiveness of the 1-step UA in the high C-factor cavity model.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2022.11.021DOI Listing

Publication Analysis

Top Keywords

high c-factor
12
universal adhesives
8
experimental 2-step
8
c-factor class-i
8
class-i cavity-bottom
8
cavity-bottom dentin
8
flowable composite
8
experimental groups
8
experimental
5
experimental two-step
4

Similar Publications

Background: Fear of progression (FoP) is among the most prevalent psychosocial burdens in paediatric oncology. Empirical evidence suggests that FoP is particularly pronounced during acute treatment and often persists into follow-up care. It is associated with heightened perception of physical symptoms, increased post-traumatic stress symptoms, more negative illness perceptions, and reduced quality of life (QoL).

View Article and Find Full Text PDF

Acute mountain sickness (AMS) usually peaks after the first night at high altitude (HA) and resolves within 2-3 days, but the effect of active ascent on AMS is debated. This study examined the incidence, severity, and time course of AMS following active versus passive ascent from 3,950 to 4,300 m. Thirty-two healthy participants traveled from low altitude (55-399 m) to 3,950 m.

View Article and Find Full Text PDF

Soil erosion is a critical environmental issue in the Brahmaputra River Basin, threatening agricultural productivity, water resources, and ecological balance. This study employs the revised universal soil loss equation (RUSLE) alongside remote sensing, geographic information systems (GIS), and advanced machine learning models like random forest (RF) and gradient boosting (GB) to analyze soil erosion patterns from 2005 to 2024. The analysis revealed that average annual soil loss increased from 15.

View Article and Find Full Text PDF

Role of configuration factor on bond strength of universal adhesives in occlusal cavities: An study.

J Conserv Dent Endod

June 2025

Department of Conservative Dentistry and Endodontics, Dr. D. Y. Patil Dental College and Hospital, Dr. D. Y. Patil Vidyapeeth, Pune, Maharashtra, India.

Introduction: During curing of composite resins, polymerization shrinkage occurs and generates stress. The configuration factor (C-factors) is an important clinical parameter and is related to polymerization shrinkage, bond strength, and durability. High C-factors indicate situations in which the material polymerizes under greater external constraint.

View Article and Find Full Text PDF

Endotoxins are common exogenous pyrogens. Excessive endotoxins in medical devices and injections can lead to serious consequences such as sepsis, septic shock, and even death. Therefore, endotoxin detection plays a crucial role in medical, pharmaceutical, and food sectors.

View Article and Find Full Text PDF