Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Although transarterial chemoembolization (TACE) is the first-line therapy for intermediate-stage hepatocellular carcinoma (HCC), it is not suitable for all patients. This study aimed to determine how to select patients who are not suitable for TACE as the first treatment choice.
Methods: A total of 243 intermediate-stage HCC patients treated with TACE at three centers were retrospectively enrolled, of which 171 were used for model training and 72 for testing. Radiomics features were screened using the Spearman correlation analysis and the least absolute shrinkage and selection operator (LASSO) algorithm. Subsequently, a radiomics model was established using extreme gradient boosting (XGBoost) with 5-fold cross-validation. The Shapley additive explanations (SHAP) method was used to visualize the radiomics model. A clinical model was constructed using univariate and multivariate logistic regression. The combined model comprising the radiomics signature and clinical factors was then established. This model's performance was evaluated by discrimination, calibration, and clinical application. Generalization ability was evaluated by the testing cohort. Finally, the model was used to analyze overall and progression-free survival of different groups.
Results: A third of the patients (81/243) were unsuitable for TACE treatment. The combined model had a high degree of accuracy as it identified TACE-unsuitable cases, at a sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of 0.759, 0.885, 0.906 [95% confidence interval (CI): 0.859-0.953] in the training cohort and 0.826, 0.776, and 0.894 (95% CI: 0.815-0.972) in the testing cohort, respectively.
Conclusions: The high degree of accuracy of our clinical-radiomics model makes it clinically useful in identifying intermediate-stage HCC patients who are unsuitable for TACE treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.hbpd.2022.11.005 | DOI Listing |