98%
921
2 minutes
20
Purpose: Portable perimetric testing could be useful for community-based glaucoma screening programs. Frequency-doubling technology (FDT) and the Moorfields motion displacement test (MDT) are portable perimeters that have shown promise as potential screening tools for glaucoma. This study's goal was to determine the diagnostic accuracy of FDT and MDT for visual field defects and glaucoma.
Design: Prospective, cross-sectional, diagnostic accuracy study.
Participants: A consecutive series of patients aged ≥ 50 years who presented to a glaucoma clinic in South India and had never undergone Humphrey field analyzer (HFA) visual field testing in the past.
Methods: Participants underwent 24-2 Swedish Interactive Thresholding Algorithm (SITA) Standard HFA perimetry, FDT perimetry, MDT perimetry, and iPad perimetry using visualFields Easy in random order. Ophthalmologist grades of HFA and optic nerve head photographs were used as reference standards for glaucoma and field defect presence. Receiver operating characteristic curves were constructed to assess the diagnostic accuracy of various parameters for each test.
Main Outcome Measures: Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC).
Results: Overall, 292 eyes from 173 participants were included, with 112 eyes classified as moderate or worse glaucoma. For moderate or worse glaucoma detection, the best parameter on FDT was mean deviation (MD) (AUROC, 0.84; 95% confidence interval [CI], 0.79-0.89) and the best parameter on MDT was global probability of true damage (GPTD) (AUROC, 0.87; 95% CI, 0.82-0.91). When specificity was set to 90%, the sensitivity for detection of moderate or worse glaucoma was 55% (95% CI, 39%-68%) for FDT MD and 62% (95% CI 52%-71%) for MDT GPTD.
Conclusions: Frequency-doubling technology and MDT perimetry had fair diagnostic accuracy for glaucoma detection when administered to naïve test takers in this South Indian population. Although not appropriate for use as a sole glaucoma screening test, these perimetric tests may be useful as ancillary tests.
Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11560139 | PMC |
http://dx.doi.org/10.1016/j.ogla.2022.11.005 | DOI Listing |
Biomaterials
August 2025
Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA. Electronic address:
Wearable bioelectronics have transformed modern biomedical applications by enabling seamless integration with biological tissues, providing continuous, comprehensive, and personalized healthcare. Skin cancer, particularly melanoma, poses a significant clinical challenge due to its high metastatic potential and associated mortality. Traditional diagnostic approaches face limitations in accuracy, accessibility, and reproducibility, while existing treatments are often constrained by systemic toxicity and therapeutic resistance.
View Article and Find Full Text PDFMicrob Genom
September 2025
Department of Infectious Diseases and Public Health, Jockey Club College of Veterinary Medicine and Life Sciences, City University of Hong Kong, Hong Kong, PR China.
African swine fever virus (ASFV) is highly transmissible and can cause up to 100% mortality in pigs. The virus has spread across most regions of Asia and Europe, resulting in the deaths of millions of pigs. A deep understanding of the genetic diversity and evolutionary dynamics of ASFV is necessary to effectively manage outbreaks.
View Article and Find Full Text PDFRetina
September 2025
Department of Ophthalmology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 15, CH-3010.
Purpose: To evaluate inter-grader variability in posterior vitreous detachment (PVD) classification in patients with epiretinal membrane (ERM) and macular hole (MH) on spectral-domain optical coherence tomography (SD-OCT) and identify challenges in defining a reliable ground truth for artificial intelligence (AI)-based tools.
Methods: A total of 437 horizontal SD-OCT B-scans were retrospectively selected and independently annotated by six experienced ophthalmologists adopting four categories: 'full PVD', 'partial PVD', 'no PVD', and 'ungradable'. Inter-grader agreement was assessed using pairwise Cohen's kappa scores.
Ophthalmol Glaucoma
September 2025
Department of Ophthalmology and Visual Sciences, University of Michigan W.K. Kellogg Eye Center, Ann Arbor, Michigan. Electronic address:
Purpose: To investigate hand function and eye drop instillation success in adults with and without glaucoma.
Design: Cross-sectional pilot study.
Subjects: Adults aged ≥ 65 years with glaucoma who use eye drops daily and adults aged 65+ without glaucoma who do not regularly use eye drops.
J Pediatr Hematol Oncol
September 2025
Department of Biostatistics, All India Institute of Medical Sciences, New Delhi, India.
Purpose: In children with Langerhans Cell Histiocytosis (LCH), FDG-PET/CT is used for staging and response assessment. Whole-body MRI (WB-MRI) can serve as an ionizing radiation-free alternative for repeated whole-body imaging. The aim of this study was to compare WB-MRI with FDG-PET/CT for staging and response assessment in pediatric LCH.
View Article and Find Full Text PDF