Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
The aim of this study was to analyze the reliability of using a differential pressure system to measure in-water force in young competitive swimmers. Ten boys and five girls (12.38 ± 0.48 years, 49.13 ± 6.82 kg, 159.71 ± 7.99 cm) were randomly assigned to perform two maximum bouts of 25 m front crawl on different days (trial one, T1; trial two, T2), one week apart. A differential pressure system composed of two hand sensors (Aquanex System, v.4.1, Model DU2, Type A, Swimming Technology Research, Richmond, VA, United States) was used to measure the peak (RF) and the mean (RF) resultant force of the dominant and non-dominant hands (in Newton, N). Reliability was analyzed by computing the intraclass correlation coefficient (ICC), typical error (TE), smallest worthwhile change (SWC), coefficient of variation (CV%), standard error of measurement (SEM), and the minimal detectable change (MDC). Bland-Altman plots with 95% limits of agreement were also analyzed. The results showed no differences between T1 and T2 in all variables ( > 0.05). The ICC showed "excellent" reliability (ICC > 0.90) for the RF and RF in both hands. The CV% was rated as "good" (<5%) and TE was smaller than SWC in all variables. The Bland-Altman plots showed high reliability with a small bias (RF dominant, -0.29 N; RF non-dominant, -0.83 N; RF dominant, 0.03 N; RF non-dominant, 0.50 N). The pressure sensor system (Aquanex System) seems to be a reliable device for measuring the hand resultant force during front crawl in young swimmers and can be used to monitor the changes over time.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9659718 | PMC |
http://dx.doi.org/10.3389/fbioe.2022.903753 | DOI Listing |