A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Anesthesia management for tracheoesophageal fistula closed with a new gastrointestinal occluder device: a case report. | LitMetric

Anesthesia management for tracheoesophageal fistula closed with a new gastrointestinal occluder device: a case report.

J Cardiothorac Surg

Department of Anesthesiology and Perioperative Medicine, First Affiliated Hospital of Nanjing Medical University, Guangzhou Road 300, Nanjing, 210029, Jiangsu Province, People's Republic of China.

Published: November 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Tracheoesophageal fistula (TEF) is a rare but life-threatening complication after esophagectomy. A new gastrointestinal occluder device provides treatment for TEF patients. However, TEF-related pneumonia and respiratory failure increase the difficulty of anesthesia management, especially in airway management.

Case Presentation: A 64-year-old man with thoracic esophageal cancer underwent esophagectomy and gastric tube reconstruction one year ago. The patient presented with recurrent cough and sputum after surgery. Gastroscopy revealed a fistula between the esophagogastric anastomotic site and membrane of the trachea. Therefore, the patient received implantation of a new gastrointestinal occluder device under gastroscopy combined with tracheoscopy. Airway management under general anesthesia was discussed with an interdisciplinary decision, and cuffed endotracheal tube with an inner diameter of 5.5 mm was chosen. This airway management ensured adequate oxygenation during the operation and provided sufficient space for the operation of the tracheoscope in the trachea. Finally, the TEF disappeared after the operation, and the patient was administered an oral diet on the first postoperative day.

Conclusions: The implantation of a new gastrointestinal occluder device under gastroscopy combined with tracheoscopy provides a new treatment for TEF patients. This case report suggests that it is important to select an endotracheal tube with an appropriate inner diameter that can not only meet the requirements of ventilation but also does not affect the operation of tracheoscopy in the trachea.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9670478PMC
http://dx.doi.org/10.1186/s13019-022-02038-8DOI Listing

Publication Analysis

Top Keywords

gastrointestinal occluder
16
occluder device
16
anesthesia management
8
tracheoesophageal fistula
8
case report
8
treatment tef
8
tef patients
8
implantation gastrointestinal
8
device gastroscopy
8
gastroscopy combined
8

Similar Publications