Differences in the Visual Performances of Patients with Strabismus, Amblyopia, and Healthy Controls.

Bioengineering (Basel)

Facultad de Ingeniería, Universidad Autónoma de Querétaro, Querétaro 76010, Mexico.

Published: October 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Unlabelled: The aim of this paper is to use the new definition of amblyopia and to define the overall visual performance of healthy controls (HCs), patients with strabismus (PS), and patients with refractive amblyopia (PRA), based on the interaction of selected visual abilities.

Method: A total of 398 participants were divided in three groups: HCs, PRA, and PS. Variables such as visual acuity, refractive state, degree of stereopsis, phoria state, magnitude, and type of deviation were analyzed using parametric and non-parametric tests.

Results: Binocular visual acuity at near is the unique predictor factor for stereopsis in PRA and PS, while age relates to the amount of binocular visual acuity at near, only for PS with stereopsis. Binocular visual acuity at near and phoria states relate to each other in PRA. Binocular visual acuity at near and far in PS is better than PRA, with no differences in the degree of stereopsis. Stereoblind patients were only found among PS (36%). Only (44.9%) of PS had amblyopia. Exophoria predominated among PRA (69.72%) and HCs (78.87%), while exotropia was the predominant deviation in PS (60.54%). Hyperopia was the predominate refractive error among the groups, HCs (74.65%), PRA (79.82%), and PS (59.85%), followed by astigmatism.

Interpretation: HCs perform better than PS and PRA. The visual performance of PS with stereopsis and PRA is similar. Binocular visual acuity at near can predict the degree of stereopsis, and stereoblind patients are exclusively related to strabismus.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9687692PMC
http://dx.doi.org/10.3390/bioengineering9110626DOI Listing

Publication Analysis

Top Keywords

visual acuity
24
binocular visual
20
degree stereopsis
12
visual
9
pra
9
patients strabismus
8
healthy controls
8
visual performance
8
groups hcs
8
stereopsis pra
8

Similar Publications

Objective: To compare the effectiveness of intravitreal faricimab and aflibercept injections in patients with polypoidal choroidal vasculopathy (PCV).

Methods: This retrospective study analysed 111 treatment-naïve eyes (111 patients) with PCV who received intravitreal injections of either faricimab (30 eyes) or aflibercept (81 eyes). All patients were treated with three initial monthly loading injections.

View Article and Find Full Text PDF

A soft micron accuracy robot design and clinical validation for retinal surgery.

Microsyst Nanoeng

September 2025

Department of Ophthalmology, Key Laboratory of Precision Medicine for Eye Diseases of Zhejiang Province, Center for Rehabilitation Medicine,, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, 314408, China.

Retinal surgery is one of the most delicate and complex operations, which is close to or even beyond the physiological limitation of the human hand. Robots have demonstrated the ability to filter hand tremors and motion scaling which has a promising output in microsurgery. Here, we present a novel soft micron accuracy robot (SMAR) for retinal surgery and achieve a more precise and safer operation.

View Article and Find Full Text PDF

Amorphous silicon resistors enable smaller pixels in photovoltaic retinal prosthesis.

J Neural Eng

September 2025

Hansen Experimental Physics Laboratory, Stanford University, 452 Lomita Mall, Stanford, California, 94305, UNITED STATES.

Clinical trials of the photovoltaic subretinal prosthesis PRIMA demonstrated feasibility of prosthetic central vision with resolution matching its 100 μm pixel width. To improve prosthetic acuity further, pixel size should be decreased. However, there are multiple challenges, one of which is related to accommodating a compact shunt resistor within each pixel that discharges the electrodes between stimulation pulses and helps increase the contrast of the electric field pattern.

View Article and Find Full Text PDF

Purpose: To report outcomes of suprachoroidal hemorrhage (SCH).

Methods: Retrospective non-randomized study of eyes with SCH from two sites (1/1/2013-12/31/2022). The primary outcome was the 6-month change in visual acuity (VA).

View Article and Find Full Text PDF

Purpose: To report reattachment rate (RR) of pars plana vitrectomy-suprachoroidal viscopexy (VIT-SCVEXY) for rhegmatogenous retinal detachment (RRD) repair. Additionally, this study compares the anatomic reattachment rate and functional outcomes of VIT-SCVEXY vs pars plana vitrectomy with traditional scleral buckle (PPV-SB) at postoperative month 3 and final follow-up.

Methods: A retrospective cohort study conducted at St.

View Article and Find Full Text PDF