A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Long-Term Vault Changes in Different Levels and Factors Affecting Vault Change After Implantation of Implantable Collamer Lens with a Central Hole. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: This study evaluated vault changes in eyes implanted with an implantable Collamer lens (ICL) with a central hole (ICL V4c) for myopia and astigmatism correction as well as factors related to vault changes over time.

Methods: This retrospective study enrolled 169 myopic eyes from 169 patients (137 women and 32 men) who underwent ICL V4c implantation to correct myopia and astigmatism. Vault values were measured quantitatively using a rotating Scheimpflug camera. Each patient underwent at least four postoperative follow-up visits at 1 month, 6 months, 1 year, and more than 2 years. We compared postoperative values between groups and identified factors affecting vault changes over time.

Results: The mean vaults at 1 month (baseline), 6 months, 1 year, and the last follow-up time following ICL implantation were 540.83 ± 186.13, 520.00 ± 196.08, 503.79 ± 198.30, and 471.42 ± 211.35 μm, respectively. Eyes with baseline vaults of 250-750 and ≥ 750 μm exhibited a trend of vault decrease over time, and the differences were statistically significant (P < 0.05) at 6 months and 1 year postoperatively, respectively. The variables relevant to the value of vault decrease between baseline and last follow-up time were anterior chamber depth (ACD) and ICL power (adjusted R = 0.121, P < 0.001).

Conclusions: We found a trend of decreased mean objective vault values over time, which was more obvious in eyes with higher baseline vault values. The vault value of the ICL decreased more in eyes with shallower ACDs, higher ICL power, or both. Moreover, the decrease in vault values became statistically significant earlier in eyes with higher baseline vaults or shallower ACDs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9834492PMC
http://dx.doi.org/10.1007/s40123-022-00606-8DOI Listing

Publication Analysis

Top Keywords

vault changes
16
factors vault
12
implantable collamer
8
collamer lens
8
central hole
8
icl v4c
8
myopia astigmatism
8
6 months 1 year
8
vault
6
long-term vault
4

Similar Publications