Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Distal radius (DR) fracture repair using the volar locked plating technique typically involves indirect fracture reduction, assessed using fluoroscopy, without direct visualization of the articular surface. This method of fracture repair may be guided by the rationale that volar radiocarpal ligament disruption may cause radiocarpal instability, although direct articular visualization may facilitate improved fracture reduction. This study investigated anatomical feasibility and articular surface visualization using volar ligament-sparing radiocarpal arthrotomy pertinent to DR fracture repair.

Methods: Ten fresh-frozen cadaveric specimens of the upper extremity underwent volar arthrotomy via the standard flexor carpi radialis approach with partial longitudinal sectioning of the long radiolunate and partial transverse sectioning of the short radiolunate ligaments to visualize the articular surface of the DR. Following arthrotomy, the visible surface of the DR was analyzed using digital photography. The wrist was disarticulated, and the fully exposed articular surface was photographed. The visible area of the articular surface was quantified using digital imaging software by calculating the ratio of the surface area visualized using the arthrotomy to the total articular surface area.

Results: The percentage of the articular surface area of the DR visualized using the volar arthrotomy was 76% ± 7.6% (range, 69%-90%), including both the scaphoid facet, lunate facet, and scapholunate ridge.

Conclusions: Volar radiocarpal arthrotomy allows clinically relevant visualization of the articular surface of the DR, including the scaphoid and lunate facets.

Clinical Relevance: Radiocarpal arthrotomy may facilitate improved articular reduction during DR fracture repair via the volar approach.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2022.08.015DOI Listing

Publication Analysis

Top Keywords

articular surface
36
radiocarpal arthrotomy
16
fracture repair
16
volar radiocarpal
12
surface area
12
area visualized
12
articular
11
surface
11
arthrotomy
8
distal radius
8

Similar Publications

Giant cell tumor (GCT) of the bone, although benign, demonstrates local aggressiveness, a potential for recurrence, and, in rare instances, malignant transformation. Functional preservation is crucial in cases involving the articular surface, often utilizing the Sandwich Technique. We propose an enhanced reconstruction method using the inner table of the iliac crest in a reverse fashion, offering a more anatomically contoured proximal tibial plateau and reducing donor site morbidity compared to tricortical iliac crest grafting.

View Article and Find Full Text PDF

Capitate Osteochondral Graft for Reconstruction of Unstable Proximal Interphalangeal Joint Injury.

JBJS Essent Surg Tech

September 2025

Division of Hand and Reconstructive Microsurgery, Department of Orthopedics, Olympia Hospital & Research Centre, Trichy, Tamilnadu, India.

Background: Hemi-hamate osteochondral grafting is a surgical technique that is utilized to reconstruct the proximal interphalangeal (PIP) joint in cases of unstable dorsal fracture-dislocation with >50% articular surface involvement. However, hemi-hamate osteochondral grafting can be technically challenging, has been reported to have various technical modifications, and can lead to complications such as overstuffing of the joint. This surgical technique article describes successful PIP joint reconstruction with use of a hemi-capitate osteochondral graft, which may offer a viable alternative to hemi-hamate osteochondral graft.

View Article and Find Full Text PDF

Background: Coronal wedge insoles are commonly prescribed to mitigate musculoskeletal disorders, yet their static-standing kinematic and kinetic effects on lower extremity joints remain insufficiently understood.

Methods: This cross-sectional experimental study included 15 healthy older adults (mean 64.9 ± 6.

View Article and Find Full Text PDF

Objective: To determine if a novel robotic system has comparable positional and angular accuracy to that achievable with patient-specific guides (PSG) when used for transcondylar screw (TCS) placement in the canine humerus.

Study Design: Experimental laboratory study.

Sample Population: A total of 32 synthetic humeral models (16 per group).

View Article and Find Full Text PDF

Introduction: CT-based classification of distal ulnar-radius fractures requires precise detection of subtle features for surgical planning, yet existing methods struggle to balance accuracy with clinical efficiency. This study aims to develop a lightweight architecture that achieves accurate AO (Arbeitsgemeinschaft für Osteosynthesefragen) typing[an internationally recognized fracture classification system based on fracture location, degree of joint surface involvement, and comminution, divided into three major categories: A (extra-articular), B (partially intra-articular), and C (completely intra-articular)] while maintaining real-time performance. In this task, the major challenges are capturing complex fracture morphologies without compromising detection speed and ensuring precise identification of small articular fragments critical for surgical decision-making.

View Article and Find Full Text PDF