Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus emerged in late 2019 leading to the COVID-19 disease pandemic that triggered socioeconomic turmoil worldwide. A precise, prompt, and affordable diagnostic assay is essential for the detection of SARS-CoV-2 as well as its variants. Antibody against SARS-CoV-2 spike (S) protein was reported as a suitable strategy for therapy and diagnosis of COVID-19. We, therefore, developed a quick and precise phase-sensitive surface plasmon resonance (PS-SPR) biosensor integrated with a novel generated anti-S monoclonal antibody (S-mAb). Our results indicated that the newly generated S-mAb could detect the original SARS-CoV-2 strain along with its variants. In addition, a SARS-CoV-2 pseudovirus, which could be processed in BSL-2 facility was generated for evaluation of sensitivity and specificity of the assays including PS-SPR, homemade target-captured ELISA, spike rapid antigen test (SRAT), and quantitative reverse transcription polymerase chain reaction (qRT-PCR). Experimentally, PS-SPR exerted high sensitivity to detect SARS-CoV-2 pseudovirus at 589 copies/ml, with 7-fold and 70-fold increase in sensitivity when compared with the two conventional immunoassays, including homemade target-captured ELISA (4 × 10 copies/ml) and SRAT (4 × 10 copies/ml), using the identical antibody. Moreover, the PS-SPR was applied in the measurement of mimic clinical samples containing the SARS-CoV-2 pseudovirus mixed with nasal mucosa. The detection limit of PS-SPR is calculated to be 1725 copies/ml, which has higher accuracy than homemade target-captured ELISA (4 × 10 copies/ml) and SRAT (4 × 10 copies/ml) and is comparable with qRT-PCR (1250 copies/ml). Finally, the ability of PS-SPR to detect SARS-CoV-2 in real clinical specimens was further demonstrated, and the assay time was less than 10 min. Taken together, our results indicate that this novel S-mAb integrated into PS-SPR biosensor demonstrates high sensitivity and is time-saving in SARS-CoV-2 virus detection. This study suggests that incorporation of a high specific recognizer in SPR biosensor is an alternative strategy that could be applied in developing other emerging or re-emerging pathogenic detection platforms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9538096PMC
http://dx.doi.org/10.1002/btm2.10410DOI Listing

Publication Analysis

Top Keywords

4 × 10 copies/ml
16
sars-cov-2 pseudovirus
12
homemade target-captured
12
target-captured elisa
12
sars-cov-2
9
severe acute
8
acute respiratory
8
respiratory syndrome
8
syndrome coronavirus
8
sars-cov-2 virus
8

Similar Publications

Background-Free Rolling Circle Amplification for SERS Bioassay Using a Chimeric Hairpin-Integrated CRISPR/Cas12a System.

Anal Chem

September 2025

State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, College of Energy, Discipline of Intelligent Instrument and Equipment, State Key Laboratory of Vaccines for Infectious Diseases, Xiang An Biomedicine Laboratory, Xiamen University, Xiamen 361

Rolling circle amplification (RCA) has revolutionized nucleic acid detection owing to its isothermal simplicity. However, over two decades of clinical application have been hampered by off-target amplification and incompatibility with double-stranded DNA (dsDNA). Herein, a strategy, specifically cleavage of rationally designed DNA/RNA chimeric hairpin preprimer by dsDNA-targeted CRISPR/Cas12a to rlease ssRNA for initiating RCA (SCOPE-RCA), is proposed for nucleic acid identification of African swine fever virus (ASFV).

View Article and Find Full Text PDF

Background: The SARS-CoV-2 virus has evolved subvariants since the emergence of the omicron variant in 2021. Whether these changes impact viral shedding and transmissibility is not known.

Methods: POSITIVES is a prospective longitudinal cohort of individuals with mild SARS-CoV-2 infection.

View Article and Find Full Text PDF

Introduction: Despite increased national and international funding to combat the human immunodeficiency virus (HIV) pandemic, prison health services remain underfunded, resulting in poor HIV management among inmates. This study assessed viral suppression rates among HIV-positive inmates across four central prisons in Cameroon to evaluate the effectiveness of antiretroviral therapy (ART) in these settings.

Methodology: This cross-sectional study included four central prisons-prisons A, B, C, and D-each located in different regions of Cameroon.

View Article and Find Full Text PDF

Switch to bictegravir/emtricitabine/tenofovir alafenamide in people living with HIV aged 65 years or older: BICOLDER study - IMEA 057.

J Infect Public Health

September 2025

AP-HP, Hospital Bichat - Claude-Bernard, Infectious and Tropical Diseases Department, IAME UMR 1137 INSERM, Université Paris Cité, France; IMEA, Hospital Bichat-Claude Bernard, Paris, France.

Background: Polymedication and comorbidities are frequent in aging people with HIV (PWH) and often associated with elevated incidences of adverse events (AEs) and drug-drug interactions (DDIs). The objective of this study was to evaluate the efficacy, safety and practicality of bictegravir/emtricitabine/tenofovir alafenamide (B/F/TAF), an antiretroviral (ARV) therapy with limited DDIs, in an elderly virologically-controlled PWH population.

Materials And Methods: This study was prospective, multicentric, single-arm conducted in HIV-1 controlled PWH aged over 65 years who switched from a ritonavir- or cobicistat-boosted containing regimen to B/F/TAF.

View Article and Find Full Text PDF

Objectives: Tobacco smoking and alcohol use may negatively influence HIV care, but associations have not been examined across cohorts.

Design: Multisite international collaboration of cohort studies.

Methods: People with HIV (PWH) were included from 11 cohorts; 5 North American and 6 Western European.

View Article and Find Full Text PDF