Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Single pixel spectroscopy based on Hadamard transform (SPS-HT) has been applied widely because of its capability of wavelength multiplexing and associated advantage in signal-to-noise ratio. In this paper, we propose a sequency encoding single pixel spectroscopy (SESPS) based on two-dimensional (2D) masks for concurrent coding of all Hadamard coefficients instead of one-dimensional (1D) Hadamard masks (only coding one coefficient at a time) widely used in the traditional SPS-HT. Moreover, each Hadamard coefficient is coded along the time dimension with a different sequency value such that the alternating current (AC) measurements of the time-domain signal can be used to reconstruct all Hadamard coefficients simultaneously, which reduces the influence of noise and dramatically speeds up data acquisition. We demonstrate that the SESPS with 32 spectral channels can accelerate spectral measurements from white light sources and fluorescence particles by around 14 times and 70 times, respectively, compared to measurements using a commercial spectrometer when the relative root mean square error (RMSE) is around 3% or smaller. The acceleration factors can be boosted by an extra 4 times when only eight spectral channels are used to achieve a compression ratio of 4:1, in which the relative RMSEs change only marginally. Compared to our previous SPS-HT, this new scheme can increase the speed by three orders of magnitude. This technique is expected to be useful in applications requiring high-speed spectral measurements such as the spectral flow cytometry and on-site medical diagnosis using fluorescence or Raman spectroscopy.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.462856DOI Listing

Publication Analysis

Top Keywords

single pixel
12
pixel spectroscopy
12
sequency encoding
8
encoding single
8
spectroscopy based
8
based hadamard
8
hadamard transform
8
hadamard coefficients
8
spectral channels
8
spectral measurements
8

Similar Publications

ChroMOS: a "microwire-like" CMOS neural probe for chronic neural recordings in mice.

Biosens Bioelectron

September 2025

Microtechnology for Neuroelectronics Unit (NetS(3) lab), Fondazione Istituto Italiano di Tecnologia, Genova, Italy.

Achieving stable and continuous monitoring of signals of numerous single neurons in the brain faces the conflicting challenge of increasing the microelectrode count while minimizing cross-sectional shank dimensions to reduce tissue damage, foreign-body-reaction and maintain signal quality. Passive probes need to route each microelectrode individually to external electronics, thus increasing shank size and tissue-damage as the number of electrodes grows. Active complementary metal-oxide-semiconductor (CMOS) probes overcome the limitation in electrode count and density with on-probe frontend, addressing and multiplexing circuits, but current probes have relatively large shank widths of 70 - 100 μm.

View Article and Find Full Text PDF

The brain is a metabolically demanding organ as it orchestrates and stabilizes neuronal network activity through plasticity. This mechanism imposes enormous and prolonged energetic demands at synapses, yet it is unclear how these needs are met in a sustained manner. Mitochondria serve as a local energy supply for dendritic spines, providing instant and sustained energy during synaptic plasticity.

View Article and Find Full Text PDF

Background: As advanced treatment plans increasingly include optimizing both dose and linear energy transfer (LET), there is a growing demand for tools to measure LET in clinical settings. Although various detection systems have been investigated in this pursuit, the scarcity of detectors capable of providing per-ion data for a fast and streamlined verification of LET distributions remains an issue. Silicon pixel detector technology bridges this gap by enabling rapid tracking of single-ion energy deposition.

View Article and Find Full Text PDF

We have developed a high-sensitivity data collection and measurement system for time-resolved x-ray diffraction experiments at the Photon Factory Advanced Ring. Use of x-ray pixel array photon counting detectors provides a suitable improvement in measurement sensitivity when compared to existing systems. The system is equipped with a laser that operates with a variable repetition rate, thus making it highly suitable for synchronization with the synchrotron x-ray source and the electronic gating detectors.

View Article and Find Full Text PDF

Scalable Photonic Crystal Sensors and Arrays Integrating Power-Free Display Interface With Dual-Mode Optical/Electrical Feedback for Real-Time Physiological Analysis.

Adv Healthc Mater

September 2025

School of Chemistry and Chemical Engineering, Guangdong Provincial Key Lab of Green Chemical Product Technology, South China University of Technology, Guangzhou, 510640, P. R. China.

Photonic crystal (PC) hydrogel-based sensors with visual signal outputs have attracted attention for wearable motion monitoring, but current devices suffer from low spatial resolution, small-scale design, and poor signal consistency. Herein, we present a combined and scalable PC sensing platform that includes a single-point sensor (100 × 400 mm) and an 8 × 8 multipixel array (100 × 100 mm) for dual-mode visual-electrical feedback. The array achieves 2D strain mapping on the arm with a spatial resolution of 0.

View Article and Find Full Text PDF