A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Diagnostic Accuracy of Direct Immunofluorescence Test on Paraffin-Embedded Blocks in Comparison with Frozen Section Blocks in Renal Biopsies. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: In several published research, the evaluation of renal disorders using immunofluorescence on formalin-fixed, paraffin-embedded (FFPE) tissue sections versus immunofluorescence on frozen sections was compared. Each technique's accuracy varies greatly. This study's objective was to assess IF-P as a potential replacement for IF-F in the diagnosis of renal biopsy specimens.

Materials And Methods: To show immunoglobulin IgA, IgG, IgM, and C3 immune deposits, proteinase K digestion of paraffin-embedded renal biopsy was standardized and used in 51 renal biopsies. Sensitivity, specificity, false-positive, and false-negative values were calculated.

Results: IF-P showed a sensitivity of 93.1%, 76.9%, 63.6%, and 33.3%, and a specificity of 100%, 97.3%, 95%, and 100% for IgG, IgA, IgM, and C3, respectively. Compared to cases that had both routine IF and IF-P, 50 of 51 showed either the same amount of staining for the diagnostic immunoglobulin/complement or a small amount of difference. In most of the cases (49 of 51), diagnostic findings were found.

Conclusion: IF-P is a sensitive and precise approach for assessing immune deposits in renal tissue biopsies. We come to the conclusion that IF-P serves as a beneficial salvage immunohistochemistry method for renal biopsies that do not contain enough cortical tissue for IF-F.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9550505PMC
http://dx.doi.org/10.1155/2022/4974031DOI Listing

Publication Analysis

Top Keywords

renal biopsies
12
renal biopsy
8
immune deposits
8
renal
7
if-p
5
diagnostic accuracy
4
accuracy direct
4
direct immunofluorescence
4
immunofluorescence test
4
test paraffin-embedded
4

Similar Publications