A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Active linearized PGC demodulation with fusion of PGC-Arctan and PGC-DCM schemes for nonlinear error elimination in SPM interferometer. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

To eliminate the nonlinear error of phase generated carrier (PGC) demodulation in sinusoidal phase modulating interferometer (SPMI), an active linearized PGC demodulation with fusion of differential-and-cross-multiplying (PGC-DCM) and the arctangent (PGC-Arctan) schemes is proposed. In this method, the periodic integer multiple of π (π-integer phases) of PGC-Arctan without nonlinear error and the corresponding PGC-DCM results recorded at the same time are fused to obtain a calibration coefficient for PGC-DCM demodulation. Combining the accurate π-integer phases of PGC-Arctan and the calibrated fractional phase in the range of π of PGC-DCM, a linearized PGC demodulation result can be achieved, effectively eliminating the nonlinear error caused by drifts of phase demodulation depth (m) and carrier phase delay (θ). The distinct advantage of the proposed method is that it actively and linearly calibrates the fractional result of PGC-DCM without needing to measure or compensate m and θ. Simulation and displacement measurement experiments with different m and inherent arbitrary θ are performed to validate the proposed method. The experimental results show that nonlinear error of the proposed method can be reduced to about 0.1 nm with real-time linearization.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.463593DOI Listing

Publication Analysis

Top Keywords

nonlinear error
20
pgc demodulation
16
proposed method
16
linearized pgc
12
active linearized
8
demodulation fusion
8
π-integer phases
8
phases pgc-arctan
8
demodulation
6
pgc-dcm
6

Similar Publications