Influence of the type of electrodes in the assessment of body composition by bioelectrical impedance analysis in the supine position.

Clin Nutr

Nutrition Unit, Service of Endocrinology, Diabetology, Nutrition and Therapeutic Education, Department of Medicine, Geneva University Hospital, Geneva, Switzerland; Faculty of Medicine, University of Geneva, Geneva, Switzerland. Electronic address:

Published: November 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background & Aims: The main source of error in body composition assessment of bedridden patients by bioelectrical impedance analysis (BIA) is the electrode inadequacy and placement. As electrocardiogram (ECG) electrodes are often used for BIA measurements, this study aimed to compare three of them with a reference BIA electrode.

Methods: BIA was performed sequentially on 24 healthy subjects in the supine position, using 3 different ECG electrodes (3M® Red Dot® 2330; Ambu® BlueSensor 2300; Ambu® BlueSensor SU-00-C) and the reference electrode (Bianostic AT®) for the BIA device (Nutriguard-M®, Data Input, Germany). Resistance (R), reactance (Xc), phase angle (PhA), appendicular skeletal muscle index (ASMI), fat-free mass index (FFMI) and fat mass percentage (FM%) obtained with the different electrodes were compared using Bland-Altman plots, repeated measures one-way ANOVA and paired t-test. Patient characteristics potentially involved in BIA measurement differences were assessed using linear regression analysis.

Results: The study population consisted of 9 men and 15 women, 33% and 47% of whom were overweight, respectively. The measured R was within the physiological range for all men (428-561 Ω) and women (472-678 Ω), regardless of the type of electrodes used. Compared to the reference electrode, the 3M® Red Dot® 2330 and Ambu® BlueSensor SU-00-C electrodes gave significantly different Xc and PhA values, but only the Ambu® BlueSensor SU-00-C gave significantly different ASMI, FFMI and FM% at 50 kHz, with biases of -0.2 kg/m, -0.3 kg/m and +1.4%, respectively. The higher the current frequency, the lower was the Xc and PhA measured by the Ambu® BlueSensor SU-00-C compared to the reference electrode. These measurement differences seemed mainly due to the too small gel area of the Ambu® BlueSensor SU-00-C (154 mm) compared to the reference electrode (1311 mm).

Conclusions: The use of electrodes with small gel area affects BIA measurement in the supine position, especially when PhA is used as an indicator of the nutritional status. Therefore, it is essential to specify the type of electrodes and carry out comparative tests before changing consumables for body composition assessment, to ensure BIA measurement reliability in clinical and research settings.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clnu.2022.09.008DOI Listing

Publication Analysis

Top Keywords

ambu® bluesensor
24
bluesensor su-00-c
20
reference electrode
16
type electrodes
12
body composition
12
supine position
12
bia measurement
12
compared reference
12
electrodes
8
bioelectrical impedance
8

Similar Publications

Influence of the type of electrodes in the assessment of body composition by bioelectrical impedance analysis in the supine position.

Clin Nutr

November 2022

Nutrition Unit, Service of Endocrinology, Diabetology, Nutrition and Therapeutic Education, Department of Medicine, Geneva University Hospital, Geneva, Switzerland; Faculty of Medicine, University of Geneva, Geneva, Switzerland. Electronic address:

Article Synopsis
  • The study investigates errors in body composition assessment of bedridden patients using bioelectrical impedance analysis (BIA) when utilizing different ECG electrodes and compares them to a reference BIA electrode.
  • Conducted on 24 healthy subjects, it finds that certain ECG electrodes, specifically the Ambu® BlueSensor SU-00-C, produced significantly different measurements for some body composition metrics compared to the reference electrode.
  • The measurement differences were linked to the smaller gel area of the Ambu® BlueSensor SU-00-C electrode, highlighting the importance of electrode adequacy in accurate body composition assessment.
View Article and Find Full Text PDF

A Mobile Sensor Network System for Monitoring of Unfriendly Environments.

Sensors (Basel)

November 2008

School of Instrument Science and Engineering, Southeast University, Nanjing, 210096, P.R. China.

Observing microclimate changes is one of the most popular applications of wireless sensor networks. However, some target environments are often too dangerous or inaccessible to humans or large robots and there are many challenges for deploying and maintaining wireless sensor networks in those unfriendly environments. This paper presents a mobile sensor network system for solving this problem.

View Article and Find Full Text PDF