Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To compare the prevalence and timing of knee surgery (including meniscal, ligamentous, synovial, and osteotomy) in the 10 years prior to primary total knee replacement (TKR) between England and Sweden.

Methods: This was a population-based, case-control study within England and southern Sweden using electronic health care databases. Patients underwent primary TKR between 2015 and 2019. Risk-set sampling showed that general population controls matched 1:1 by age, sex, and practice/municipality. The annual prevalence and prevalence ratio of having at least 1 recorded surgery in each of the 10 years preceding TKR was estimated using Poisson regressions.

Results: We included 6,308 and 47,010 TKR cases in Sweden and England, respectively. Meniscal surgeries were the most frequent procedure prior to TKR in both countries; prevalence was higher in England across all time points. The prevalence of meniscal surgery increased in both countries in the years approaching TKR, reaching 33.2 (95% confidence interval [95% CI] 31.6-34.9) per 1,000 persons in England, and 9.83 (95% CI 7.66-12.61) in Sweden. In England, we observed a decrease from 2014 to 2018 in the utilization of this procedure in the 4 years preceding a TKR. The prevalence of all analyzed surgeries was consistently lower in controls.

Conclusion: There are comparable trends in the use of knee surgery in the years preceding TKR across England and Sweden. Of note, meniscal surgeries remain common, even within the year prior to TKR, highlighting that these patients may experience low-value care. Careful consideration of knee surgery in those with late-stage disease is required.

Download full-text PDF

Source
http://dx.doi.org/10.1002/acr.25033DOI Listing

Publication Analysis

Top Keywords

total knee
12
knee replacement
12
knee surgery
12
preceding tkr
12
tkr
9
england
8
england sweden
8
tkr england
8
sweden england
8
meniscal surgeries
8

Similar Publications

Micro-Strain Responsive Near-Infrared Mechanoluminescence for Potential Nondestructive Artificial Joint Stress Imaging.

Adv Mater

September 2025

Key Laboratory of In-Fiber Integrated Optics of Ministry of Education, College of Physics and Optoelectronic Engineering, Harbin Engineering University, Harbin, 150001, China.

Recently, joint replacement surgery is facing significant challenges of patient dissatisfaction and the need for revision procedures. In-situ monitoring of stress stability at the site of artificial joint replacement during postoperative evaluation is important. Mechanoluminescence (ML), a novel "force to light" conversion technology, may be used to monitor such bio-stress within tissues.

View Article and Find Full Text PDF

Introduction: We attempted to perform a comprehensive bioinformatics analyses on osteoarthritis (OA) based on the NKT-related genes and explore the clinical related critical genes.

Methods: Differentially expressed genes (DEGs) and NKT-related genes from WGCNA were obtained using the dataset GSE114007, followed by intersection analysis to obtain NKT-related DEGs. Lasso regression, support vector machine and random forest were performed to screen feature genes, followed by verification with ROC curve, and nomogram model.

View Article and Find Full Text PDF

Introduction/background: Complex articular fractures around the knee in the elderly patient present an ongoing challenge regarding optimal treatment. While extensive research has evaluated immediate arthroplasty following fracture of the proximal femur, distal femur, proximal humerus, and elbow, relatively little focus has been given to immediate arthroplasty following complex tibia plateau fractures.

Methods: As seen with many other fractures, arthroplasty can shorten recovery and hospital stay and allow early weight-bearing with improved mobility while minimizing complications and possible future conversion arthroplasty cost.

View Article and Find Full Text PDF

Purpose: Robotic-assisted total knee arthroplasty (RA-TKA), which is increasingly used to improve surgical precision, can face adoption difficulties due to a learning curve marked by longer operating times. The aim of this study was to evaluate the learning curve associated with the VELYS™ robot in five surgeons from the same centre with different annual arthroplasty volumes using navigated assistance with personalised alignment. The primary aim was to assess the learning curve for each surgeon.

View Article and Find Full Text PDF

Purpose: To assess the functional and subjective outcomes of combined anterior cruciate ligament reconstruction (ACLR) and lateral meniscal root tear (LMRT) repair. Additionally, to compare the use of an independent tunnel for LMRT repair with the ACL bone tunnel technique and to assess the failure rates of LMRT repair to isolated ACLR.

Methods: Patients who underwent primary ACLR and concomitant LMRT repair from May 2017 to May 2022 at Capio Artro Clinic, Stockholm, Sweden, were retrospectively identified and matched 1:3 (age, sex and graft type) with patients who underwent isolated ACLR during the same period.

View Article and Find Full Text PDF