Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

HLA-mismatched hematopoietic stem cell micro-transplantation (MST) is an effective treatment for older patients (≥60 years) with acute myeloid leukemia. Donor selection for MST is broad, ranging from HLA fully mismatched unrelated donors to HLA partially matched related donors. However, the influence of HLA haplotype homozygous donors such donors on MST has not been studied. Such donors has been reported to be associated with a higher risk of graft-versus-host disease (GVHD) in transfusion and cord blood transplantation (CBT). Additionally, sustained complete donor chimerism is rare in MST and usually accompanied by severe acute GVHD and death. Herein, we report the first case of MST using an HLA haplotype homozygous donor. The patient developed persistent complete donor chimerism (donor cells>95%) for 7 months and prolonged isolated thrombocytopenia (PT) for 3 months, after receiving MST from his HLA homozygous son. Grade I acute GVHD presented on day 12 post-MST and it was controlled by timely immunosuppressive treatment. Then he maintained complete molecular remission, complete donor chimerism and mild GVHD for 5 months. However, moderate overlapping GVHD with skin, oral, eyes, and intestinal involvement developed after he self-discontinued Tacrolimus treatment. Fortunately, the GVHD was controlled after intensive anti-rejection therapy and Tacrolimus is now being continued for prophylaxis. This case underscores that HLA haplotype homozygous donors might not be a good choice for MST and GVHD prophylactic should be administrated if such donors have to be selected.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9521673PMC
http://dx.doi.org/10.3389/fimmu.2022.1005364DOI Listing

Publication Analysis

Top Keywords

complete donor
16
donor chimerism
16
hla haplotype
16
haplotype homozygous
16
homozygous donors
12
persistent complete
8
gvhd
8
donors
8
acute gvhd
8
mst hla
8

Similar Publications

Objectives: This study aimed to compare the efficacy of the full-thickness palatal graft technique (FTPGT) and the coronally advanced flap with subepithelial connective tissue graft (CAF + SCTG) in achieving complete root coverage (CRC) in single gingival recessions (GR).

Methods: Forty healthy patients with a single RT1 GR were randomized into two groups: 20 treated with CAF + SCTG and 20 with FTPGT. Baseline and 12-month measurements of GR, keratinized tissue width (KTW), probing depth (PD), clinical attachment level (CAL), and gingival thickness (GT) were recorded.

View Article and Find Full Text PDF

All-small-molecule organic solar cells (ASM-OSCs) with completely definite chemical structure are an ideal model to establish the relationship between molecular structure and device performance via aggregates. The end-capped acceptor unit is of great significance in the regulation of aggregates by essential molecular interactions. However, the successful end-capped acceptor units for small-molecule donors have been rather poorly studied and only focused on the alkyl substituted rhodamine, limiting further development for ASM-OSCs.

View Article and Find Full Text PDF

Nontargeted Screening of Fingermark Residue Using Comprehensive Two-Dimensional Gas Chromatography-Time-of-Flight Mass Spectrometry for Future Use in Forensic Applications.

J Am Soc Mass Spectrom

September 2025

Nontargeted Separations Laboratory, Chemistry Department, William & Mary, Integrated Science Center 1053, 540 Landrum Drive, Williamsburg, Virginia 23188, United States.

Fingerprints are routinely used as evidence in forensic investigations. Fingermarks, any mark left by a donor whether a complete print or not, include sweat and oil excreted by the donor. The chemical components of fingermarks are typically analyzed by gas chromatography-mass spectrometry (GC-MS).

View Article and Find Full Text PDF

Donor-acceptor-donor (D-A-D) thiophene-based compounds, characterized by thiophene as a donor unit and benzothiadiazole (Bz) as an acceptor, represent an emerging class of theranostic agents for imaging and photodynamic therapy. Here, we expand this class of molecules by strategically varying the position of the electron-accepting unit within the oligothiophene (OT) backbone structure, realizing a series of different push-pull architectures (A-D, D-A-D, and D-A). This rational design allows for precise modulation of key photophysical parameters, including absorption and emission spectra, molar absorption coefficient, charge separation, and frontier molecular orbitals.

View Article and Find Full Text PDF

Evaluation of automatic staplers for renal artery division in laparoscopic donor nephrectomy: impact of vessel diameter on hemostatic outcomes.

Surg Endosc

September 2025

Department of Surgery and Oncology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.

Background: Laparoscopic donor nephrectomy requires precise renal artery management for optimal outcomes. This study evaluates the performance and safety of automatic staplers in dividing renal arteries of various diameters.

Methods: Experimental tests were conducted using porcine arteries (3, 5, and 7 mm) to compare double- and triple-row staplers in terms of stapling completeness and pressure resistance.

View Article and Find Full Text PDF