98%
921
2 minutes
20
Purpose To assess interreader agreement of the Ovarian-Adnexal Reporting and Data System (O-RADS) and intermodality concordance between US and MRI for characterizing complex adnexal cysts measuring 5 cm or larger. Materials and Methods This retrospective study included 58 "complex cysts" measuring at least 5 cm in size observed at both US and MRI in 54 women (median age, 37 years ± 12 [SD]; seven postmenopausal women) between July 2017 and June 2020, identified from an electronic US database. A separate set of two blinded radiologists independently reviewed the US or MR images to assign the O-RADS category, and an adjudicator resolved discrepancies (a total of six readers). Lesion outcome (49 benign, eight malignant, one lost to follow-up) was recorded. Interreader agreement of O-RADS US and O-RADS MRI and concordance between US and MRI were analyzed. Results Interreader agreement was fair for US (κ = 0.31), moderate for MRI (κ = 0.43), and moderate between US and MRI (κ = 0.58). A significant positive correlation was found between O-RADS US and MRI (τ = 0.72, < .001). The O-RADS 4 threshold yielded the highest accuracy for both US and MRI (area under the receiver operating characteristic curve = 0.92 and 0.995, respectively). Considering O-RADS US 4 or 5 as potentially malignant and 1-3 as benign, eight lesions that were assessed as potentially malignant at US were correctly downgraded to benign by using findings at MRI. Using findings at MRI, one malignant lesion that was assessed as benign at US was upgraded to potentially malignant. Conclusion O-RADS US and MRI had excellent performance and positive correlation, but significant interobserver variability remains. Ovary, MR Imaging, Ultrasonography © RSNA, 2022 See also the commentary by Baumgarten in this issue.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9530774 | PMC |
http://dx.doi.org/10.1148/rycan.220064 | DOI Listing |
Eur Radiol Exp
September 2025
Department of Orthopaedics and Trauma Surgery, Orthopaedic Oncology, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.
Computed tomography (CT) and magnetic resonance imaging (MRI) are commonly used to assess femoral and tibial torsion. While CT offers high spatial resolution, it involves ionizing radiation. MRI avoids radiation but requires multiple sequences and extended acquisition time.
View Article and Find Full Text PDFSkeletal Radiol
September 2025
Department of Radiology, Federal University of Sao Paulo (UNIFESP), Napoleão de Barros St, 800, São Paulo, SP, 04024-000, Brazil.
Objective: To evaluate multiparametric MRI features of pediatric soft-tissue sarcomas, comparing pre-treatment and post-treatment features, and assessing correlation with clinical outcomes.
Materials And Methods: Retrospective cohort study, including pediatric patients (≤ 18 years) with histologically-confirmed soft-tissue sarcomas who underwent MRI with anatomic and functional sequences in consecutive series. Post-treatment MRI was available for a subset, and features were recorded by two readers.
Introduction: Precise prediction of pathological complete response (pCR) following neoadjuvant chemoradiotherapy (nCRT) in rectal cancer may identify candidates for non-operative management. The optimal selection of diagnostic tools is therefore of major clinical importance.
Methods: Clinical, laboratory, endoscopic and radiological data of patients with rectal cancer treated with nCRT and surgery at an academic medical center from 2010 to 2020 were retrospectively collected.
Eur J Radiol
August 2025
Department of Radiology, Pusan National University School of Medicine and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Beomeo-ri, Mulgeum-eup, Yangsan-si 626-770 Gyeongsangnam-do, Republic of Korea. Electronic address: kschoo061
Objectives: This study externally tests the performance of an artificial intelligence algorithm (AI) for diagnosing ascending aortic dilatation (AAD) using PA view chest radiography (PA CXR).
Materials And Methods: Two retrospectively collected cohorts with paired CXR/CT within 30 days (Group 1) and 90 days (Group 2) were gathered as external test sets. The performance of AI (DeepCatch X Aorta v1.
J Neuroimaging
September 2025
Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Medical Institution, Baltimore, Maryland, USA.
Background: Alzheimer's disease (AD) and mild cognitive impairment (MCI) are two common conditions associated with cognitive decline. With global dementia cases rising, identifying the most accurate imaging method for diagnosis is essential.
Methods: Following Preferred Reporting Items for Systematic review and Meta-Analysis Protocols, we systematically reviewed studies utilizing arterial spin labeling magnetic resonance imaging (ASL-MRI) and [18F]-2-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) for neurodegenerative disorders.