98%
921
2 minutes
20
Objectives: Totally laparoscopic total gastrectomy has been developed with difficulty in intracorporeal esophagojejunostomy. Although mechanical stapling has been widely used for intracorporeal esophagojejunostomy, manual suture holds great promise with the emergence of high-resolution 3D vision and robotic surgery. After exploration of how to improve the safety and efficiency of intracorporeal suture for esophagojejunostomy, we recommended the technique of single-layer running "trapezoid-shaped" suture. The cost-effectiveness was analyzed by comparing with conventional mechanical stapling.
Methods: The study retrospectively reviewed the patients undergoing laparoscopic gastrectomy for gastric cancer from January 2010 to December 2021. The patients were divided into two cohorts based on the methods of intracorporeal esophagojejunostomy: manual suture versus stapling suture. Propensity score matching was performed to match patients from the two cohorts at a ratio of 1:1. Then group comparison was made to determine whether manual suture was non-inferior to stapling suture in terms of operation time, anastomotic complications, postoperative hospital stay, and surgical cost.
Results: The study included 582 patients with laparoscopic total gastrectomy. The manual and stapling suture for esophagojejunostomy were performed in 50 and 532 patients, respectively. In manual suture cohort, the median time for the whole operation and digestive tract reconstruction were 300 min and 110 min. There was no anastomotic bleeding and stenosis but two cases of anastomotic leak which occurred at 3 days after surgery. The median length of postoperative hospital stay was 11 days. After propensity score matching, group comparison yielded two variables with statistical significance: time for digestive tract reconstruction and surgery cost. The manual suture cohort spent less money but more time for esophagojejunostomy. Intriguingly, the learning curve of manual suture revealed that the time for digestive tract reconstruction was declined with accumulated number of operations.
Conclusions: Laparoscopic single-layer running "trapezoid-shaped" suture appears safe and cost-effective for intracorporeal esophagojejunostomy after total gastrectomy. Although the concern remains about prolonged operation time for beginners of performing the suture method, adequate practice is expected to shorten the operation time based on our learning curve analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00423-022-02694-3 | DOI Listing |
This study aimed to evaluate the resistance of anastomoses to mechanical traction in an ex vivo biomechanical experiment, to determine the most resistant manual suture for restoring digestive tract continuity after various types of gastric resection for cancer. Materials and methods: The tensile strength of different types of anastomoses was compared ex vivo using porcine esophagus, stomach, and small intestine. The test setup included a tensile testing device, which applied a controlled force on the anastomoses until they broke, which was recorded for each type of anastomosis and was expressed in N.
View Article and Find Full Text PDFZhonghua Wei Chang Wai Ke Za Zhi
August 2025
Department of Gastroenterology, the First Affiliated Hospital of Wenzhou Medical University, Wenzhou 325035, China.
To explore the application value of right-opening single flap valvuloplasty based on tubular stomach in gastrointestinal reconstruction after laparoscopic proximal gastrectomy. Use a linear cutting stapler to make a parallel curve from the angle of the stomach to the junction of the gastric fundus to remove the lesser curvature of the stomach, and detach the gastric body about 5 cm away from the tumor to create a tubular stomach. Use a marker pen to draw a C-shaped seromuscular flap area with a width of 2.
View Article and Find Full Text PDFAnn Vasc Surg
August 2025
Division of Vascular and Endovascular Surgery, Department of Surgery, Boston University Chobanian and Avedisian School of Medicine, Boston Medical Center, Boston, MA. Electronic address:
Background: Arteriovenous (AV) access bleeding requires prompt management, but little is known about short- and long-term outcomes after these events. Our goal was to evaluate emergency management of AV access bleeds and their outcomes.
Methods: This is a retrospective analysis of emergency department (ED) visits for AV access bleeding at a tertiary care center between 2014 and 2022.
Sci Data
August 2025
Birmingham City University, Birmingham, United Kingdom.
Indexing endoscopic surgical videos is vital in surgical data science, forming the basis for systematic retrospective analysis and clinical performance evaluation. Despite its significance, current video analytics rely on manual indexing, a time-consuming process. Advances in computer vision, particularly deep learning, offer automation potential, yet progress is limited by the lack of publicly available, densely annotated surgical datasets.
View Article and Find Full Text PDFCornea
August 2025
Instituto de Oftalmologia Fundacion Conde de Valenciana IAP, Mexico City, Mexico; and.
Purpose: To describe the surgical technique for implantation of a novel flexible, suturable, intrastromal synthetic cornea device.
Methods: This report is a description of a novel surgical technique. Adult patients (≥18 years) with corneal edema who met specific inclusion criteria were enrolled.