A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Simulation and Experimental Investigation of the Vacuum-Enhanced Direct Membrane Distillation Driven by a Low-Grade Heat Source. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Vacuum-enhanced direct contact membrane distillation (VEDCMD) has been proven experimentally to improve the permeate flux, compared with direct contact membrane distillation (DCMD). However, the theoretical mechanism for its transmembrane transfer process has not been revealed sufficiently. In this paper, with full consideration of the different driving forces of diffusion and Poiseuille flow under the vacuum enhancing condition, a theoretical transmembrane model for mass and heat transfer in VEDCMD is proposed. The CFD model and experimental platform are established to verify the theoretical model. The simulated results agree with the experimental data well, and nearly 200% improvement of the permeate flux is obtained when the permeate pressure drops to 30 kPa. The flow fields of the flow along the membrane surface are obtained and analyzed, with good consistency in the variation of the permeate flux. Since all the parameters of the proposed model are independent of the operating condition, the model is much easier for use and has better adaptability to fluctuating operating conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9504430PMC
http://dx.doi.org/10.3390/membranes12090842DOI Listing

Publication Analysis

Top Keywords

membrane distillation
12
permeate flux
12
vacuum-enhanced direct
8
direct contact
8
contact membrane
8
model
5
simulation experimental
4
experimental investigation
4
investigation vacuum-enhanced
4
membrane
4

Similar Publications