A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Use of RT-PCR thermocycling program for the quantification of DNA viruses in a single run with RNA viruses: Example of Altona RealStar® HSV or VZV PCR kits. | LitMetric

Use of RT-PCR thermocycling program for the quantification of DNA viruses in a single run with RNA viruses: Example of Altona RealStar® HSV or VZV PCR kits.

Infect Dis Now

Laboratoire de Virologie, Centre Hospitalier Universitaire (CHU) Grenoble - Alpes, 38000 Grenoble, France; Institut de Biologie Structurale (IBS), UMR 5075 CEA-CNRS-Université Grenoble-Alpes, 38000 Grenoble, France. Electronic address:

Published: November 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Real-time PCR plays a key role in the diagnosis of viral infections. Multiple kits can detect or quantify genomes of various viruses with the same thermocycling program. Detection of RNA viruses includes an additional step of reverse transcription and challenge their detection in a single run with DNA viruses. We investigated the analytical performance of HSV-1, HSV-2 and VZV DNA quantification with Altona RealStar® PCR kits using the RT-PCR program for RNA viruses instead of the PCR program for DNA viruses. For each three viruses, Bland-Altman distribution did not show differences between both programs, and quantification curves generated with both thermocycling programs confirmed high correlation (R ≥ 0.9983). Detection of low viral load samples was evaluated, on 10-times repeat-test. All replicate samples were detected with both thermocycling programs and were quantified at similar viral loads (bias in log copies/mL: +0.05 (HSV-1), -0.01 (HSV-2) and +0.25 (VZV)). This confirms the feasibility of using the RT-PCR thermocycling program to detect and quantify the genome of RNA and DNA viruses in a single run.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.idnow.2022.09.005DOI Listing

Publication Analysis

Top Keywords

dna viruses
16
thermocycling program
12
rna viruses
12
viruses
9
rt-pcr thermocycling
8
viruses single
8
altona realstar®
8
pcr kits
8
detect quantify
8
thermocycling programs
8

Similar Publications