A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Extractable denuders for selective sampling of vapour phase organics in the atmosphere. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Extractable denuders were designed to collect trace atmospheric semivolatile organic compounds with high volume (38.30 and 200 L/ min) samplers. Denuders were made of multichannel ceramic support coated with sodium silicate and functionalised with phenyl moieties. Polycyclic aromatic hydrocarbons, polychlorinated biphenyls, polychlorinated dibenzodioxins and polychlorinated dibenzofurans and chlorobenzenes in ambient air of a sub-urban area of Monterotondo, Italy, were sampled. Samplings were of 24 h, 48 h and 1 week period. Precision was determined using field triplicates and compared to the conventional high volume sampler methods. The fraction of analytes in the particle phase measured with the filter/ PUF system ranged from 0.2 % for naphthalene to 98.5 % for benzo(ghi)perylene; this fraction measured with the denuder ranged from 0.5 % for naphthalene to 99.0 % for benzo(ghi)perylene. A paired t-test indicated that these values were significantly (t = 3.58, P < 0.01) higher for the denuder. Results showed good repeatability (0.4-4.6 %), sampling efficiency (>99 %) and good capacity as variations in experimental efficiency were not observed also for longer (1 week) period sampling. As significant changes in efficiency were observed (0.7-5.6 %), the developed denuder cannot be reused more than once. However, it is possible to regenerate the denuder with a new silanization step. A good linear correlation was found plotting the vapour/particle distribution ratio versus the vapour pressure (R ranged between 0.59 and 0.84) and versus the octanol/air partition coefficient (R ranged between 0.85 and 0.88) of each selected SVOCs, in good agreement with the theoretical models for partitioning of SVOCs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2022.158744DOI Listing

Publication Analysis

Top Keywords

extractable denuders
8
high volume
8
week period
8
ranged naphthalene
8
efficiency observed
8
denuders selective
4
selective sampling
4
sampling vapour
4
vapour phase
4
phase organics
4

Similar Publications