98%
921
2 minutes
20
Objectives: The impacts of ventilation tube (VT) type and effusion composition on the VT extrusion rate and complications in children with otitis media remain unclear. This part II study evaluated the factors affecting the extrusion rate, recurrence rate, and complications of VT insertion.
Methods: A prospective study was conducted between June 2014 and December 2016 (the EVENT study [analysis of the effectiveness of ventilation tube insertion in pediatric patients with chronic otitis media]), with follow-up data collected until the end of 2017. Patients aged <15 years diagnosed with otitis media with effusion who received VT insertion were recruited at 15 tertiary hospitals. The primary outcomes were time to extrusion of VT, time to effusion recurrence, and complications.
Results: Data from 401 patients were analyzed. After excluding the.
Results: of long-lasting tubes (Paparella type II and T-tubes), silicone tubes (Paparella type I) exhibited a significantly longer extended time to extrusion (mean, 400 days) than titanium tubes (collar-button-type 1.0 mm: mean, 312 days; P<0.001). VT material (hazard ratio [HR], 2.117, 95% confidence interval [CI], 1.254-3.572; P=0.005), age (HR, 3.949; 95% CI, 1.239-12.590; P=0.02), and effusion composition (P=0.005) were significantly associated with the time to recurrence of middle ear effusion. Ears with purulent (mean, 567 days) and glue-like (mean, 588 days) effusions exhibited a shorter time to recurrence than ears with serous (mean, 846 days) or mucoid (mean, 925 days) effusions. The revision VT rates during follow-up were 3.5%, 15.5%, 10.4%, and 38.9% in ears with serous, mucoid, glue-like, and purulent effusions, respectively (P<0.001). The revision surgery rates were higher among patients aged <7 years than among those aged ≥7 years.
Conclusion: Silicone tubes (Paparella type I) were less prone to early extrusion than titanium 1.0 mm tubes. VT type, patient age, and effusion composition affected the time to recurrence of effusion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9723292 | PMC |
http://dx.doi.org/10.21053/ceo.2022.00934 | DOI Listing |
Resuscitation
September 2025
Department of Pediatrics, Division of Neonatology, The Children's Hospital of Philadelphia and The University of Pennsylvania Perelman School of Medicine, Division of Neonatology, 2(nd) Floor, Main Building, 3401 Civic Center Boulevard, Philadelphia, PA 19104, USA.
Aim: Flow disruptions (FDs) are deviations in the progression of care that compromise safety and efficiency of a specific process. Neonatal intubation is a life-saving high-risk procedure required for delivery room (DR) management of neonates with moderate to severe congenital diaphragmatic hernia (CDH). This study evaluated FDs during DR intubation of neonates with CDH and their association with process and outcome measures.
View Article and Find Full Text PDFCerebellum
September 2025
Department of Neurology, Faculty of Medicine, Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
Multiple system atrophy (MSA) is a progressive, adult-onset neurodegenerative disorder involving autonomic failure, cerebellar ataxia, and parkinsonism. Patients often require invasive interventions, such as gastrostomy or tracheostomy, and sudden death is common. This study aimed to elucidate patterns of invasive treatment and identify risk factors for tracheostomy or sudden death within 5 years of onset.
View Article and Find Full Text PDFFront Surg
August 2025
Department on Anesthesia and Surgery, Faculty of Medicine, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh, Saudi Arabia.
Patulous Eustachian Tube (PET) dysfunction is a rare condition characterized by an abnormally open Eustachian tube, leading to symptoms such as autophony, auditory fullness, and pulsatile tinnitus. This case report describes a 48-year-old female weighing 72.4 kilograms who developed persistent autophony and hearing her own breathing and heartbeat sounds following significant weight loss after sleeve gastrectomy.
View Article and Find Full Text PDFIntensive Crit Care Nurs
August 2025
Shuguang Hospital Affliated to Shanghai University of Traditional Chinese Medicine, Clinical Research Center, Shanghai 201203, China. Electronic address:
Objectives: To compare the effectiveness of various endotracheal tube (ETT) cuff materials, shapes, and antimicrobial coatings in preventing ventilator-associated pneumonia (VAP) through a network meta-analysis.
Methods: Six databases were searched up to February 2025 for relevant randomized controlled trials (RCTs). Data analysis was performed using R software.
Resuscitation
September 2025
Ruhr University Bochum, Medical Faculty of Ruhr University Bochum, Universitätstraße 150, 44801 Bochum, Germany; University Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Medicine, Johannes Wesling Klinikum Minden, Ruhr University Bochum, Hans-Nolte-Straße 1, 3
Background: This study aimed to evaluate the efficacy of Chest-Compression-Synchronized-Ventilation (CCSV) using supraglottic airway devices (SGA) compared to tracheal intubation (TI) for ventilation during continuous resuscitation.
Methods: In this cross-over study, the lungs of adult Thiel-embalmed cadavers were initially recruited using TI. Subsequently, various SGA (Laryngeal-Mask=Ambu®AuraGain™, Laryngeal-Tube=LTS-D®, i-gel-Laryngeal-Mask=I-GEL®) and TI were applied in randomized order during continuous chest compressions.