Article Abstract

Type 1 diabetes (T1D) is associated with lower scores on tests of cognitive and neuropsychological function and alterations in brain structure and function in children. This proof-of-concept pilot study (ClinicalTrials.gov Identifier NCT03428932) examined whether MRI-derived indices of brain development and function and standardized IQ scores in adolescents with T1D could be improved with better diabetes control using a hybrid closed-loop insulin delivery system. Eligibility criteria for participation in the study included age between 14 and 17 years and a diagnosis of T1D before 8 years of age. Randomization to either a hybrid closed-loop or standard diabetes care group was performed after pre-qualification, consent, enrollment, and collection of medical background information. Of 46 participants assessed for eligibility, 44 met criteria and were randomized. Two randomized participants failed to complete baseline assessments and were excluded from final analyses. Participant data were collected across five academic medical centers in the United States. Research staff scoring the cognitive assessments as well as those processing imaging data were blinded to group status though participants and their families were not. Forty-two adolescents, 21 per group, underwent cognitive assessment and multi-modal brain imaging before and after the six month study duration. HbA1c and sensor glucose downloads were obtained quarterly. Primary outcomes included metrics of gray matter (total and regional volumes, cortical surface area and thickness), white matter volume, and fractional anisotropy. Estimated power to detect the predicted treatment effect was 0.83 with two-tailed, α = 0.05. Adolescents in the hybrid closed-loop group showed significantly greater improvement in several primary outcomes indicative of neurotypical development during adolescence compared to the standard care group including cortical surface area, regional gray volumes, and fractional anisotropy. The two groups were not significantly different on total gray and white matter volumes or cortical thickness. The hybrid closed loop group also showed higher Perceptual Reasoning Index IQ scores and functional brain activity more indicative of neurotypical development relative to the standard care group (both secondary outcomes). No adverse effects associated with study participation were observed. These results suggest that alterations to the developing brain in T1D might be preventable or reversible with rigorous glucose control. Long term research in this area is needed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9427757PMC
http://dx.doi.org/10.1038/s41467-022-32289-xDOI Listing

Publication Analysis

Top Keywords

hybrid closed-loop
16
care group
12
closed-loop insulin
8
insulin delivery
8
delivery system
8
type diabetes
8
primary outcomes
8
volumes cortical
8
cortical surface
8
surface area
8

Similar Publications

Management of diabetes mellitus in hemodialysis is highly complex due to increased glycemic variability and hypoglycemic risk. The use of technologies applied to diabetes has been shown to improve glycemic control, however data in dialysis patients are limited. To describe the efficacy and safety of the minimed 780G AHCL system in a stable hemodialysis patient and during hospitalization in the Intensive Care Unit (ICU).

View Article and Find Full Text PDF

CamAPS FX is a customizable hybrid closed-loop app with a default target glucose of 105 mg/dL. The personal glucose target is user-adjustable in 1 mg/dL increments between 80 and 198 mg/dL in 30-min segments over 24 h. We assessed the impact of different personal glucose targets on glycemic control during real-world use of CamAPS FX in different age-groups.

View Article and Find Full Text PDF

Hybrid pneumatic-hydraulic actuation for MRI-guided robotic stereotactic neurointervention.

Sci Adv

September 2025

Shanghai Key Laboratory of Flexible Medical Robotics, Tongren Hospital, Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200336, China.

Stereotactic neurointervention is a common procedure for biopsy, injection, ablation, and implantation of electrodes for deep brain stimulation. Guided by preoperative imaging, conventional approaches are mostly performed manually, lacking operation stability and interactive feedback. The intraoperative magnetic resonance imaging (MRI) guidance enables both structural and functional assessment during operation, permitting interactive adaptation to tissue deformation and avoidance of critical anatomical regions.

View Article and Find Full Text PDF

Continuous glucose monitoring (CGM) has transformed diabetes mellitus management, evolving from a supportive monitoring tool to a central pillar of care. For people with type 1 diabetes and many insulin-treated individuals with type 2 diabetes, CGM now directly informs treatment decisions, especially when integrated with automated insulin delivery (AID) systems. In these hybrid closed-loop systems, sensor data drives real-time insulin adjustments, meaning that accuracy is not just a matter of measurement quality; it is a matter of patient safety.

View Article and Find Full Text PDF

This case report describes a 25-year-old woman with type 1 diabetes mellitus (T1DM) and autoimmune thyroid disease (AITD) who developed Addison disease (AD). The diagnosis was suspected due to a significant decrease in insulin requirement and recurrent hypoglycemia despite adjustments in insulin pump therapy. The patient exhibited typical clinical features of AD, including hyperpigmentation and electrolyte imbalances.

View Article and Find Full Text PDF