Objective: To evaluate a novel fully automated immunoturbidimetric assay developed by Qiangsheng Biotechnology Company for the detection of anticyclic citrullinated peptide antibodies (anti-CCP) in serum of patients with rheumatoid arthritis (RA) and compare it to the conventional EUROIMMUN- anti-CCP ELISA. Two other commonly used automated assays, the Elecsys anti-CCP assay, an ECLIA that is run on the Modular Analystics E170 (Cobas Diagnostics, Germany), and an anti-CCP CLIA developed by YHLO that is run on the iFlash 3000 Chemiluminescence Immunoassay Analyzer, were included as reference standards.

Methods: A total of 264 serum samples were collected from patients attending the First People's Hospital of Wenling affiliated to Wenzhou Medical University between July 2020 and November 2020. These included 131 serum samples collected from patients with RA, 70 serum samples collected from patients with other autoimmune diseases, and 63 serum samples collected from healthy controls at a physical examination. The clinical performance and sensitivity and specificity of the four anti-CCP assays for the diagnosis of RA were compared using receiver operating characteristic (ROC) curve analysis.

Results: The Kappa statistic indicated almost perfect agreement between the EUROIMMUN-anti-CCP ELISA and the Elecsys anti-CCP ECLIA (Cobas) (0.863), the EUROIMMUN-anti-CCP ELISA and the anti-CCP CLIA (YHLO) (0.862), and the Elecsys anti-CCP ECLIA (Cobas) and the anti-CCP CLIA (YHLO) (0.816). On ROC curve analysis, AUC values were 0.955 for the EUROIMMUN-anti-CCP ELISA, 0.948 for the anti-CCP CLIA (YHLO), 0.947 for the Elecsys anti-CCP ECLIA (Cobas) and 0.903 for Qiangsheng, indicating all the assays had a good diagnostic performance for RA.

Conclusion: The anti-CCP assays provided similar diagnostic information. The novel fully automated immunoturbidimetric assay for anti-CCP developed by Qiangsheng Biotechnology Company may be especially useful for large scale clinical screening in RA as it has a shorter testing time than the commercially available alternatives.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9380855PMC
http://dx.doi.org/10.3389/fimmu.2022.940713DOI Listing

Publication Analysis

Top Keywords

elecsys anti-ccp
16
anti-ccp clia
16
serum samples
16
samples collected
16
anti-ccp
13
collected patients
12
euroimmun-anti-ccp elisa
12
anti-ccp eclia
12
eclia cobas
12
clia yhlo
12

Similar Publications

Objective: To evaluate a novel fully automated immunoturbidimetric assay developed by Qiangsheng Biotechnology Company for the detection of anticyclic citrullinated peptide antibodies (anti-CCP) in serum of patients with rheumatoid arthritis (RA) and compare it to the conventional EUROIMMUN- anti-CCP ELISA. Two other commonly used automated assays, the Elecsys anti-CCP assay, an ECLIA that is run on the Modular Analystics E170 (Cobas Diagnostics, Germany), and an anti-CCP CLIA developed by YHLO that is run on the iFlash 3000 Chemiluminescence Immunoassay Analyzer, were included as reference standards.

Methods: A total of 264 serum samples were collected from patients attending the First People's Hospital of Wenling affiliated to Wenzhou Medical University between July 2020 and November 2020.

View Article and Find Full Text PDF

Introduction/objectives: Anti-cyclic citrullinated peptide antibody (anti-CCP) is one of the most important serologic markers for diagnosing rheumatoid arthritis (RA). This study aimed to compare the analytical and clinical performances of the second- and third-generation anti-CCP assays.

Methods: Four automated anti-CCP assays were evaluated: Chorus anti-CCP (Diesse Diagnostica), Elecsys anti-CCP (Roche Diagnostics), Atellica® IM anti-CCP IgG (Siemens Healthineers), and Quanta Flash® CCP3 (Inova Diagnostics Inc.

View Article and Find Full Text PDF

Anti-cyclic citrullinated peptide antibodies (anti-CCPs) are important diagnostic markers for rheumatoid arthritis (RA). We evaluated the analytical and clinical performance of the QUANTA Flash CCP3 (INOVA Diagnostics, USA), a fully automated third-generation anti-CCP assay, in comparison with three second-generation anti-CCP (CCP2) assays. A total of 300 sera (67 from RA patients, 64 from other rheumatic diseases, 43 from osteoarthritis [OA], and 126 from other conditions) were tested with QUANTA Flash CCP3, Kallestad Anti-CCP II (Bio-Rad, USA), Elecsys Anti-CCP (Roche Diagnostics GmbH, Germany), and ARCHITECT Anti-CCP (Abbott Diagnostics, USA).

View Article and Find Full Text PDF

Diagnostic utility of the Elecsys anti-CCP assay in patients with rheumatoid arthritis.

Mod Rheumatol

July 2014

Translational Medicine Research Center, School of Pharmaceutical Sciences, Xiamen University, Xiamen, Fujian , P. R. China.

Objective: The automatic anti-cyclic citrullinated peptide (anti-CCP) antibodies assay offered great advantages over traditional methods in terms of improved precision, reliability, technical simplicity, short turnaround time and high-speed throughput. In this study, we evaluated the main technical performance and diagnostic accuracy of the first automatic anti-CCP assay approved in China.

Methods: The study comprised 106 rheumatoid arthritis (RA) patients, 203 non-RA rheumatic disease controls and 46 healthy persons.

View Article and Find Full Text PDF

Objectives: Anti-cyclic citrullinated peptide (anti-CCP) antibodies are highly specific markers of rheumatoid arthritis (RA). Considering the heterogeneity of the target antigens involved, and the test platforms and conjugates proposed in commercial anti-CCP assays, we assessed the diagnostic performances of four fully automated anti-CCP assays in a cohort of patients with RA compared to patients with other autoimmune and inflammatory disorders. We also evaluated the agreement between the qualitative results of these immunoassays.

View Article and Find Full Text PDF