Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Statement Of Problem: Cinnamaldehyde has been successfully used for the short-term disinfection of dentures; however, its long-term effects on the surface and color properties of denture base materials remain unknown.

Purpose: The purpose of this in vitro study was to evaluate the effects of simulated immersion in cinnamaldehyde for up to 5 years on the surface roughness and color parameters of a heat-polymerized denture resin.

Material And Methods: Eighty Ø10×5-mm disk-shaped specimens were prepared from microwave heat-polymerized polymethylmethacrylate (PMMA) and immersed in 4 solutions (n=20): TW-tap water (control), SH - 0.5% sodium hypochlorite, PX-alkaline peroxide, and CA-cinnamaldehyde (27 μg/mL). The immersion protocol simulated 104 cycles (3.5 months), 913 cycles (2.5 years), and 1825 immersion cycles (5 years) of a daily immersion cleaning protocol, with immersion times ranging from 10 to 20-minutes. Surface roughness (Sa) and the color parameters of CIELab (L∗ a∗ b∗, ΔEab), CIEDE2000 (ΔE00), and the National Bureau of Standards (NBS) were analyzed at baseline (t=0) and after the immersion cycles. The data were analyzed by 2-way analysis of variance (ANOVA) for repeated measures and the Tukey post hoc test (α=.01).

Results: Sa was significantly increased in all groups after 1825 cycles compared with baseline (P<.01), regardless of the solution. Only the time factor significantly affected ΔEab, ΔE00, and NBS parameters, which were below the perceptibility and acceptability thresholds. After a simulated 5-year immersion, the surface roughness and color values of CA-treated specimens were not statistically different from those of the other groups (P>.01).

Conclusions: Cinnamaldehyde solution (27 μg/mL) produced minor effects on the surface roughness and color parameters of a heat-polymerized denture base resin similar to those of 0.5% sodium hypochlorite and alkaline peroxide after a 5-year simulated immersion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2022.07.002DOI Listing

Publication Analysis

Top Keywords

surface roughness
16
roughness color
16
heat-polymerized denture
12
denture base
12
color parameters
12
immersion
8
base resin
8
effects surface
8
simulated immersion
8
parameters heat-polymerized
8

Similar Publications

Using fingermark powders and lifters on rhino horn to support anti-poaching efforts.

Sci Justice

September 2025

Department of Analytical, Environmental and Forensic Sciences, Institute of Pharmaceutical Science, King's College London, 150 Stamford Street, London SE1 9NH, UK. Electronic address:

Wildlife poaching and the trade of wildlife items is a large area of illegal business that is alleged to be worth hundreds of billions of dollars. However, wildlife forensics remains an understudied field even though the consequences of poaching are catastrophic and can lead to the spread of zoonotic disease and a decrease in biodiversity. Even though fingermark analysis is cost-effective, easy to deploy in the field and has a long history of securing criminal convictions in court, wildlife forensics is mainly limited to DNA-based techniques.

View Article and Find Full Text PDF

This study aimed to characterize, in vitro dissolution, and evaluate the release kinetics of salicylamide in capsule shells made from κ-carrageenan-HPMC. The capsule shell was prepared using the dipping method with CRG: HPMC (1:1, 1:2, 1:3) ratio, supplemented with sorbitol and antifoam silicone emulsion. Characterization was conducted using FTIR, SEM-EDX mapping, AFM, hardness, and swelling degree experiments.

View Article and Find Full Text PDF

This study assessed the effect of saliva exposure on roughness (Ra) and Vickers hardness (VHN) of two direct restorative materials, enamel, and dentin adjacent to the restorations. Enamel and dentin cavities in molars (n = 10) were restored with a) bulk-fill resin composite (Tetric N-Flow Bulk Fill, BF) with the application of a universal adhesive (Tetric N-Bond Universal) and b) alkasite restorative material (Cention N, CN) with and without the application of a universal adhesive. After 24 h (baseline), surface roughness and hardness of the restorative material and dental tissues were assessed at 100 μm from the tooth/restoration interface.

View Article and Find Full Text PDF

Single electrons confined to a free neon surface and manipulated through the circuit quantum electrodynamics architecture is a promising novel quantum computing platform. Understanding the exact physical nature of the electron-on-neon (eNe) charge states is important for realizing this platform's potential for quantum technologies. We investigate how resonator trench depth and substrate surface properties influence the formation of eNe charge states and their coupling to microwave resonators.

View Article and Find Full Text PDF

Introduction: This study investigated the effect of sandblasting time and primer type on the shear bond strength of composite attachments to full-contour zirconia crowns.

Methods: A total of 108 zirconia specimens were fabricated and divided into 9 groups (n = 12) according to sandblasting time (10, 30, and 60 seconds) and primer type (silane, 10-methacryloyloxydecyl dihydrogen phosphate [MDP], universal). After sandblasting with 110-μm alumina particles, specimens were primed, and attachments were bonded using a packable composite.

View Article and Find Full Text PDF