98%
921
2 minutes
20
Various implant wrapping methods with acellular dermal matrix (ADM) have been introduced, but most focus on random trimming and suturing aimed to maximize implant coverage. Here we present our clinical experience using a "tear-drop appearance" wrapping method to achieve natural contours through upper pole volume replacement. We retrospectively reviewed the data of 56 consecutive cases of prepectoral prosthetic-based breast reconstruction (PPBR) using this wrapping method following nipple-sparing mastectomy between March 2020 and June 2021. The "tear-drop appearance" wrapping design creates an anatomical tear-drop-shaped pocket to encourage lower pole fullness and create a natural contour through upper pole volume replacement by ADM. Patients' baseline characteristics, operative data, and complications were analyzed. Aesthetic outcomes were measured using the BREAST-Q and Aesthetic Item Scale (AIS). A successful reconstruction was achieved without major complications and using a single ADM sheet. Four types and three sizes of ADMs were used. The mean resected breast tissue weight was 274.3 g, while the mean implant volume was 230.0 cc. The average BREAST-Q and AIS scores were 4.6 ± 0.8 and 4.5 ± 0.7, respectively. Owing to its simplicity, reproducibility, and effectivity, this method is an excellent implant coverage option that achieves a natural contour in PPBR.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9370020 | PMC |
http://dx.doi.org/10.3390/jcm11154592 | DOI Listing |
ACS Omega
April 2024
The University of Burdwan, Burdwan, West Bengal 713104, India.
This study addresses the increasing concern about naphthalene, a polycyclic aromatic hydrocarbon (PAH), highlighting its growing threats to the environment and aquatic life. The research examines its impact on (Bloch) through a detailed dose-specific bioenzymological analysis. Experimental fish groups were exposed to T1 (0.
View Article and Find Full Text PDFJ Clin Med
August 2022
Department of Plastic and Reconstructive Surgery, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan 49267, Korea.
Various implant wrapping methods with acellular dermal matrix (ADM) have been introduced, but most focus on random trimming and suturing aimed to maximize implant coverage. Here we present our clinical experience using a "tear-drop appearance" wrapping method to achieve natural contours through upper pole volume replacement. We retrospectively reviewed the data of 56 consecutive cases of prepectoral prosthetic-based breast reconstruction (PPBR) using this wrapping method following nipple-sparing mastectomy between March 2020 and June 2021.
View Article and Find Full Text PDFJ Xray Sci Technol
September 2013
Department of Radiology, the First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, China.
This study aims to analyze magnetic resonance imaging (MRI) features of ejaculatory duct obstruction, and to provide an accurate diagnostic imaging approach for surgical planning of minimally invasive procedures treating ejaculatory duct obstruction. A total of 18 men with ejaculatory duct obstruction were enrolled in the study. The patients were admitted to our hospital and had undergone MRI examination and surgical treatment from January 2003 to February 2011.
View Article and Find Full Text PDF