A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Knee adduction moment is correlated with the increase in medial meniscus extrusion by dynamic ultrasound in knee osteoarthritis. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: An increase in medial meniscus extrusion (MME) due to abnormal biomechanical stress leads to knee osteoarthritis (OA) progression. MME evaluation during walking is a key method of detecting dynamic changes in the meniscus, and in combination with motion analysis, can provide a deeper understanding of the mechanisms involved in the increase of MME.

Objective: To validate the feasibility of MME dynamic evaluation in combination with a motion analysis system based on the correlation between the increase in MME and biomechanical factors.

Methods: Twenty-three knees from 23 patients with mild to moderate knee OA were analysed in this study. The medial meniscus during walking was evaluated by ultrasound. The increase in MME was calculated as the difference between the minimum and maximum MME during walking. A three-dimensional motion analysis system was synchronised with the ultrasound and then, biomechanical factors such as knee moment and ground reaction force were evaluated.

Results: The wave patterns of the mediolateral and vertical components of ground reaction forces and knee adduction moment were similar to those in the MME based on a high cross-correlation coefficient (>0.8). The increase in MME was significantly correlated with the peak value of the knee adduction moment (r = 0.54, P = 0.0073) but not with the mediolateral and vertical components of the ground reaction force.

Conclusion: The findings show that knee adduction moment is correlated with an increase in MME during walking and indicates the validity and feasibility of the dynamic evaluation of MME in combination with a motion analysis system.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.knee.2022.07.011DOI Listing

Publication Analysis

Top Keywords

knee adduction
16
adduction moment
16
motion analysis
16
increase mme
16
medial meniscus
12
combination motion
12
analysis system
12
ground reaction
12
mme
10
knee
8

Similar Publications