Article Abstract

The purpose of the present study was to evaluate the mechanical resistance of elastodontic devices (ED): their maximum compression loads and plastic deformation under loading (percentage). An Instron universal machine (Model 3365, Instron, Industrial Product Group, Grove City, PA, USA) was employed with a 100 N load cell and with Bluehill software for loading analyses. Each device was submitted to a five-cycles test. The following ED were evaluated: A.M.C.O.P. (Micerium, Genova, Italy) in red color, in orange color, and in blue color; HealthyStart (Ortho-Tain, Winnetka, IL, USA), and T4K™ phase 1 (Myofunctional Research Co., Helensvale, Australia). During the five-cycles test, the Ortho-Tain device delivered the greatest compression load (7.56 N), with the lowest percentage of deformation (0.95%). For all devices, a slight plastic deformation of the material was registered, ranging from 0.95% to 1.75%. For the T4K device it was not possible to complete the five-cycles test. For all the analyzed ED, a slight plastic deformation under loading was registered, that in all cases can be considered clinically acceptable. Further studies are needed to test the appliances after clinical usage.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9312014PMC
http://dx.doi.org/10.3390/bioengineering9070282DOI Listing

Publication Analysis

Top Keywords

deformation loading
12
plastic deformation
12
five-cycles test
12
elastodontic devices
8
slight plastic
8
deformation
5
devices orthodontics
4
orthodontics in-vitro
4
in-vitro study
4
study mechanical
4

Similar Publications

We have developed a new true triaxial apparatus for rock deformation, featuring six servo-controlled loading rams capable of applying maximum stresses of 220 MPa along the two horizontal axes and 400 MPa along the vertical axis to cubic rock samples of 50 mm side. Samples are introduced into a steel vessel, allowing rock specimens to be subjected to confining pressures of up to 60 MPa. Pore fluid lines connected to two pump intensifiers enable high-precision permeability measurements along all three principal stress directions.

View Article and Find Full Text PDF

To investigate the clinicopathological features, diagnosis, and prognosis of aggressive natural killer-cell leukemia (ANKL). A retrospective analysis was conducted on 27 ANKL patients treated at the First Affiliated Hospital of Nanjing Medical University from 2014 to 2024. Their clinical data, histomorphology, and immunophenotype were reviewed.

View Article and Find Full Text PDF

Effect of Drill Handle Force Applied to Digital Surgical Guides on Implant Deviation: An In Vitro Study.

Clin Implant Dent Relat Res

October 2025

State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, China.

Introduction: This in vitro study evaluated how different forces applied to the dental drill handle during static computer-assisted implant surgery influence surgical guide deformation and implant placement accuracy.

Methods: Twenty-four virtual implants were divided into six groups (0-10 N, in 2 N increments). Surgical guides were scanned under loaded conditions, and deviations were quantified by superimposition with the baseline model.

View Article and Find Full Text PDF

The most significant challenge facing magnesium alloy stents is their ability to withstand complex deformation during their application. To gain a deeper understanding of the impact of stent deformation on the protective capabilities of the coating, this paper presents an amplified stent deformation model. The models were coated with either a low elongation material-Poly(D, L-lactide) (PDLLA) or a high elongation material-Poly(butylene adipate-co-terephthalate) (PBAT), followed by the application of a rapamycin-loaded PLGA as drug-eluting layer.

View Article and Find Full Text PDF

Background/objective: Plate failure, including bending, is a critical issue in orthopedic fracture fixation, with clinical failure rates of 3.5%-19%, burdening patients and healthcare systems. Preclinical ovine models have observed similar plate bending due to overloading.

View Article and Find Full Text PDF