Article Abstract

Objective: To investigate the steps faculty surgeons take upon experiencing intraoperative error and synthesize these actions to offer a framework for coping with errors.

Background: While intraoperative errors are inevitable, formal training in error recovery is insufficient and there are no established curricula that teach surgeons how to deal with the intraoperative error. This is problematic because insufficient error recovery is detrimental to both patient outcomes and surgeon psychological well-being.

Methods: We conducted a thematic analysis. One-hour in-depth semistructured interviews were conducted with faculty surgeons from 3 hospitals. Surgeons described recent experiences with intraoperative error. Interviews were transcribed and coded. Analysis allowed for development of themes regarding responses to errors and coping strategies.

Results: Twenty-seven surgeons (30% female) participated. Upon completion of the analysis, themes emerged in 3 distinct areas: (1) Exigency, or a need for training surgical learners how to cope with intraoperative errors, (2) Learning, or how faculty surgeons themselves learned to cope with intraoperative errors, and (3) Responses, or how surgeons now handle intraoperative errors. The latter category was organized into the STOPS framework: Intraoperative errors could produce STOPS: Stop, Talk to your Team, Obtain Help, Plan, Succeed.

Conclusions And Relevance: This study provides both novel insight into how surgeons cope with intraoperative errors and a framework that may be of great use to trainees and faculty alike.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SLA.0000000000005447DOI Listing

Publication Analysis

Top Keywords

intraoperative errors
24
intraoperative error
16
faculty surgeons
12
cope intraoperative
12
intraoperative
10
surgeons
9
error recovery
8
errors
7
error
6
stops coping
4

Similar Publications

Background: Staging laparoscopy (SL) is an essential procedure for peritoneal metastasis (PM) detection. Although surgeons are expected to differentiate between benign and malignant lesions intraoperatively, this task remains difficult and error-prone. The aim of this study was to develop a novel multimodal machine learning (MML) model to differentiate PM from benign lesions by integrating morphologic characteristics with intraoperative SL images.

View Article and Find Full Text PDF

Purpose: To discuss the technique and outcome of what the authors called the "flap-in-flap" technique and report its safety as a procedure for correction of post-laser in situ keratomileusis (LASIK) myopic regression.

Methods: Seven eyes of 4 patients were included in this study. All patients had previously undergone LASIK for compound myopic astigmatism using the Moria M2 micro-keratome (Moria) 8 to 12 years prior to presentation.

View Article and Find Full Text PDF

Computer-assisted surgery and planning in percutaneous pelvic screw fixation.

Orthop Traumatol Surg Res

September 2025

CHU de Grenoble-Alpes, Université de Grenoble-Alpes, Laboratoire TIMC-IMAG, Unité de Chirurgie Orthopédique et Traumatologique, CNRS UMR 5525, Boulevard de la Chantourne, 38700 La Tronche, France.

Percutaneous pelvic screwing (PPS) enables fixation of traumatic or atraumatic fractures with little or no displacement, or displaced but reduced fractures, and preventive fixation of primary or secondary tumoral lesions. It is a relatively recent technique, and indications are evolving with progress in pre- and intra-operative imaging. Morbidity is lower than with open surgery.

View Article and Find Full Text PDF

Purpose: Replicating spinal cord injury (SCI) in large animals is necessary for evaluating translational therapeutics, yet there is currently no commercial, standardized device for inducing SCI. We present the fabrication and testing of a custom impactor device for producing repeatable contusion SCI in porcine models.

Methods: The device was built, and mechanical modeling was utilized for calibration.

View Article and Find Full Text PDF

Dynamic joint balancing (DJB) in robotic-assisted total knee arthroplasty (RATKA) allows surgeons to simulate implant positioning and predict soft tissue balance intraoperatively before bone resection. Although virtual gap (VG) estimation is integral to this process, its accuracy in predicting the final gap (FG) after implantation remains uncertain. We conducted a retrospective analysis of 77 knees in 61 patients undergoing RATKA with the MAKO system.

View Article and Find Full Text PDF