Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To identify pre-surgical imaging predictive value and factors associated with the clinicopathologic discrepancy for implication of definitive pelvic radiotherapy in clinically node-negative bladder cancer.

Method: The documented data of bladder cancer patients who underwent radical cystectomy plus pelvic lymphadenectomy were collected retrospectively. Patients' characteristics, last imaging, pathology reports, disease-specific survival and overall survival were retrieved.

Results: From 142 patients, pre-surgical imaging had a sensitivity of 76.4%, specificity of 73.7%, positive predictive value (PPV) of 94.9%, and negative predictive value (NPV) of 32.6% (p value < 0.0001) for detection of muscle invasion. Also, for detection of positive lymph nodes, imaging had a sensitivity of 31.8%, specificity of 85.7%, PPV of 50%, and NPV of 73.7% (p value: 0.022). 44.4% of study population were upstaged after surgery (24.6% associated with N-upstaging) and 18.3% were downstaged (12% associated with N-downstaging). Receipt of neoadjuvant chemotherapy and T-stage were not correlated with N-upstaging. On multivariate analysis, lymphovascular invasion (LVI) maintained its significance for independent prediction of upstaging (OR 3.3, 95% CI 1.5-7.5, p value: 0.004) and inversely with downstaging (OR 0.34, 95% CI 0.12-0.96, p value: 0.04). Older age (OR 1.03, 95% CI 1.0-1.05, p value 0.047), positive margins (OR 2.1, 95% CI 1.2-3.8, p value 0.011), presence of LVI (OR 2.5, 95% CI 1.4-4.7, p value 0.003), perineural invasion (OR 2.0, 95% CI 1.2-3.4, p value 0.013), and lymph node ratio (OR 1.011, 95% CI 1.001-1.021, p value 0.03) were associated with worse survival. Also, N-upstaging independently predicted a worse survival after controlling for surgical pathology stage (OR 2.3, 95% CI 1.2-4.5, p value 0.011).

Conclusions: The optimal target volume in definitive chemoradiotherapy of node-negative bladder cancer patients remains to be established. Since then, customizing the treatment is considered especially for positive LVI in TURBT specimen.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11796696PMC
http://dx.doi.org/10.1007/s00432-022-04153-4DOI Listing

Publication Analysis

Top Keywords

bladder cancer
8
predictive factors
8
clinicopathologic discrepancy
8
pre-surgical imaging
8
implications pelvic
4
pelvic lymph
4
lymph node
4
node irradiation
4
irradiation definitive
4
definitive chemoradiotherapy
4

Similar Publications

Background: Rhabdomyosarcoma (RMS) typically responds well to a combination of treatments with favorable prognosis in children 1 to 9 years old. However, infants may fare worse due to receiving less aggressive local therapy for concerns about long-term effects of surgery/radiation. This study investigates the clinical characteristics, treatment approach, and survival outcomes of RMS in children under 2.

View Article and Find Full Text PDF

Long-term complications in patients with bladder-prostate rhabdomyosarcoma treated with brachytherapy: a systematic review.

Pediatr Surg Int

September 2025

Pediatric Surgery Unit, Department of Women's and Children's Health, University of Padua, Via Nicolò Giustiniani, 35100, Padua, Italy.

Introduction: Brachytherapy has been used for the multimodal treatment of pediatric bladder-prostate rhabdomyosarcoma in the last two decades. The aim of this systematic review is to gather the current evidence about this innovative technique with a special focus on long-term outcomes.

Methods: According to PRISMA criteria, PubMed, Scopus, and Web of Science were searched for papers published between 2000 and 2022.

View Article and Find Full Text PDF

Background: High-dose-rate (HDR) brachytherapy is essential in the treatment of locally advanced cervical cancer. While Iridium-192 (Ir-192) is commonly used, its short half-life imposes logistical and financial constraints, particularly in low- and middle-income countries (LMICs). Cobalt-60 (Co-60), with a longer half-life and lower operational costs, is a viable alternative.

View Article and Find Full Text PDF