A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Diffusive gradients in thin films (DGT) probe for effectively sampling of per- and polyfluoroalkyl substances in waters and sediments. | LitMetric

Diffusive gradients in thin films (DGT) probe for effectively sampling of per- and polyfluoroalkyl substances in waters and sediments.

J Environ Sci (China)

Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China. Electronic address:

Published: November 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The passive sampling technique, diffusive gradients in thin films (DGT) has attracted increasing interests as an in-situ sampler for organic contaminants including per- and polyfluoroalkyl substances (PFAS). However, its effectiveness has been questioned because of the small effective sampling area (3.1 cm). In this study, we developed a DGT probe for rapid sampling of eight PFAS in waters and applied it to a water-sediment system. It has a much larger sampling area (27 cm) and as a result lower method quantification limits (0.15 - 0.21 ng/L for one-day deployment and 0.02 - 0.03 ng/L for one-week deployment) and much higher (by > 10 factors) sampling rate (100 mL/day) compared to the standard DGT (piston configuration). The sampler could linearly accumulate PFAS from wastewater, was sensitive enough even for a 24 hr deployment with performance comparable to grab sampling (500 mL). The DGT probe provided homogeneous sampling performance along the large exposure area. The use of the probe to investigate distributions of dissolved PFAS around the sediment-water interface was demonstrated. This work, for the first time, demonstrated that the DGT probe is a promising monitoring tool for trace levels of PFAS and a research tool for studying their distribution, migration, and fate in aquatic environments including the sediment-water interface.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jes.2021.09.003DOI Listing

Publication Analysis

Top Keywords

dgt probe
16
diffusive gradients
8
gradients thin
8
thin films
8
films dgt
8
sampling
8
per- polyfluoroalkyl
8
polyfluoroalkyl substances
8
sampling area
8
sediment-water interface
8

Similar Publications